ECOJET / ECOSTAR 1500 DISPENSER INSTALLATION
MOUNTING AND WIRING THE DISPENSER
1. Locate a suitable location for dispensers. Mount Z-Bracket using appropriate mounting hardware.
Dispenser weighs 80 pounds, make sure it is mounted securely.
2. Mount tempering valve and RPZ. Connect hot and cold water supply to tempering valve. Connect
output of tempering valve to RPZ.
3.
Adjust hot and cold regulators on tempering valve to 30 p.s.i.
NOTE: During operation, no more than 20 PSI should be present at the flush manifolds.
Peristaltic pumps cannot accurately pump against flush pressures that exceed 20-25 psi
4. Mount USER INTERFACE on washer. Mount WASHER SIGNAL INTERFACE
5. Wire washer signals to WASHER SIGNAL INTERFACE
6. Wire 3-conductor wire from WASHER SIGNAL INTERFACE to USER INTERFACE. (see
diagram on page 10)
7. Wire 5-conductor wire from USER INTERFACE to PUMP BOARD located in right side of EcoJet /
EcoStar 1500 DISPENSER. (see diagram on page 10)
8. After all wiring is complete, plug in EcoJet / EcoStar 1500 and switch on. The USER INTERFACE
display should appear and 01 should display on LED read out.
9. Before programming and wiring the multi-link cable, the USER INTERFACE MUST BE ERASED
and NETWORK ADDRESS ENTERED( Dispenser ID).
EcoStar 1500
EcoStar
s i g n a l i n t e r f a c e m o d u l e
signal indicators
SIGNAL #1
SIGNAL #2
SIGNAL #3
SIGNAL #4
SIGNAL #5
SIGNAL #6
ECOLAB
washer signals
USER
INTERFACE
WASHER
INTERFACE
MODULE
ECOJET /
ECOSTAR
1500
3 CONDUCTOR
WIRE
5 CONDUCTOR
WIRE
TIP: BEFORE
wiring the multilink
cable to the pump
boards, you
MUST ERASE
the memory and
set the TIME and
DATE of each
user interface.