TROUBLE SHOOTING
USER INTERFACE
LOW LEVEL ALARM - During an out of product alarm, the dispenser with the low drum alarm wired to it will
sound the alarm. The first line of the USER INTERFACE will display LOW LEVEL ALARM! The external alarm
strobe will light and the buzzer will sound a continuous tone.
TO RESET: Replace empty drum. Press RESET on USER INTERFACE with the low-level alarm.
FLUSH ERROR: During a FLUSH ERROR, the EcoJet / EcoStar 1500 has detected low water flow through
the flush manifold. The first line of the USER INTERFACE will display FLUSH ERROR! The external alarm
strobe will light and the built-in buzzer will sound an intermittent tone.
TO RESET: Press RESET on affected dispenser. Locate reason for flush error.
REPORTS
PROBLEM
SOLUTION
NO INFORMATION FOR A GIVEN PERIOD
Incorrect date in User Interface or no data for
selected period
RUNTIME ERROR 76 DURING
REPORT GENERATION
Do not use
“ ‘, : \ < > in the filename.
ECOJET / ECOSTAR 1500 / ECOJET DISPENSER
PROBLEM
POSSIBLE CAUSE
SOLUTION
COLLAPSED LINE FROM PUMP OUTPUT
TO FLUSH MANIFOLD or INCONSISTENT
PRODUCT DELIVERY
High water flush pressures
Reduce flush presure
to below 20 PSI.
SIGNAL INTERFACE MODULE
INDICATORS LIGHT, BUT PUMPS DO NOT
RUN
Signal duration not long enough
Decrease signal
qualify time
USER INTERFACE WILL NOT LIGHT
§
Dispenser not plugged in.
§
Dispenser not turned on.
§
Fuses burned out on pump
board
Plug in, Switch on,
Check fuses
FLUSH ERROR DISPLAYED ON USER
INTERFACE
§
Water Supply volume low,
tuned off
Check Water Supply
and Tempering Valves
LOW LEVEL ALARM DISPLAYED ON
USER INTERFACE
Empty Drums
Change Drum
UNABLE TO LOG IN TO NETWORK
MultiLink network not wired
properly, wrong dispenser ID.
Check MultiLink
network for proper
connection and wiring.
Check Account and
Network Locations.