4.2.2 Settings
Mode
(7=ON, 8=OFF)
Speed
Delay
(e.g. 10 sec)
Dosage time
(e.g. 6 sec)
Analog
4.2.3 Delay: (DIP switch “Delay | Mode |”)
(Mode setting)
Obligatory
(Mode setting)
Obligatory
32 seconds
16 seconds
8 seconds
4 seconds
2 seconds
1 second
4.2.4 Dosage time: (DIP switch “TIME/Titration”)
Not used
Not used
64 seconds
32 seconds
16 seconds
8 seconds
4 seconds
2 seconds
When all “
TIME
” DIP-switches are OFF, the dosage time is 1 second
4.2.5 Enable signals
-
Contact closed at input “
IN1
” (Enable switch / pressure switch)
-
Contact closed at input “
IN2
” (Low level input)