ADJUSTMENT OF GAS MINIMUM PRESSURE SWITCH
Unscrew off and remove cover M. - Set regulator N to a value equal to 60% of gas nominal
feed pressure (i.e. for nat. gas nom. pressure = 20 mbar, set regulator to a value of 12 mbar;
for L.P.G. nom. pressure of G30/G31- 30/37 mbar, set regulator to a value of 18
mbar).Screw up cover M
ADJUSTMENT OF THE AIR PRESSURE SWITCH
Unscrew screws A and B and remove cover C.- Set the pressure switch to the mini-
mum by turning regulator D to position 1.
- Start the burner and keep in low flame running, while checking that combustion is
correct. Through a small cardboard, progressively obstruct the air intake until to
obtain a CO
2
increase of 0,5÷0,8% or else, if a pressure gauge is available, connected
to pressure port E, until reaching a pressure drop of 1 mbar (10 mm of W.G.). -
Slowly increase the adjustment value of the air pressure switch until to have the bur-
ner lockout. Remove the obstruction from the air intake, screw on the cover C and
start the burner by pressing the control box rearm button.
Note: The pressure measured at pressure port E must be within the limits of the
pressure switch working range. If not, loose the locking nut of screw F and gradually
turn the same: clockwise to reduce the pressure; counterclockwise to increase. At the
end tighten the locking nut.
2,5
5
10
15
50
2
5
3
5
3
0
40
45
20
0,4
0,6
0,9
3
,0
1,
5
2,1
1,8
2,4
2,7
1,2
I
L
M
N
A
B
C
D
E
F
G
H
gas pressure
switch
air pressure switch
The detector current is checked by inserting a microam-
meter (scale 1000 µA - d.c.) in series with the uv cell..
The flame detector current has to been > 70 µA.
DETECTOR CURRENT
22 23
LANDIS
�
LFL 1.622
Fotocellula
min 70
μ
A
Microamperometro �
fondo scala 1000
μ
A
UV CELL
Microamperometer
full scale 1000 µA
LFL 1.333
REMOVING THE BLAST TUBE
REMOVING THE FIRING HEAD
Содержание Multiflam 300.1
Страница 85: ...85 420010309500 Multiflam 300 1 400 1 PR PR RU SUNTEC TA C4 1 2 3 4 5 6 1 2 5 6 3 4 0 45 22 25 3 T...
Страница 87: ...87 420010309500 Multiflam 300 1 400 1 PR PR RU 50 E 50 C 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 10 11 50 E 50 C...
Страница 88: ...88 420010309500 Multiflam 300 1 400 1 PR PR RU 5 fig B...
Страница 90: ...90 420010309500 Multiflam 300 1 400 1 PR PR RU F I H E G N A D Q O P D E F G I N O P Q...
Страница 96: ...96 420010309500 Multiflam 300 1 400 1 PR PR RU 1 2 CO2 9 5 9 8 CO 75 ppm C 0 70 A 2 3 2 3 2 3 2 3...