HIGH PRESSURE BURNER
INSTALLATION & OPERATING INSTRUCTIONS
The appliance should be installed in accordance with the following:
•
AS/NZS 5601.1: gas installations part 1: general installations
•
Manufacturer’s installation instructions;
•
Local gas fitting regulations;
•
Municipal building codes; and
•
Any other relevant statutory regulation.
The appliance must be installed, serviced and removed by an authorised person only.
IMPORTANT:
•
Carefully read and understand this Installation & Operating Instruction booklet in full
•
Familiarise yourself with the appliance BEFORE connecting the appliance to the gas cylinder
•
Retain this manual for future reference
•
You MUST purchase a suitable regulator and hose assembly
REGULATOR AND HOSE ASSEMBLY DETAILS
This appliance must be connected to a certified hose and regulator assembly to ensure safe operation as
follows: Propane Gas regulator fitted with a POL type inlet fitting, outlet pressure of 100 kPa and Certified to
AS4621 and an 8mm High Pressure hose (maximum length 1.8 metres) certified to AS/NZS 1869 class ‘C’ or
‘D’. The hose outlet fitting required to ensure compatibly with the inlet connection of this appliances is ¼” BSP
female threaded nut and 60º inverted flare.
THE CORRECT ASSEMBLY MUST BE USED - DO NOT USE ADAPTORS
The use of any equivalent certified hose/regulator assembly compliant with the requirements above is
FOR OUTDOOR USE ONLY