7
FIGURE 3
Well
Pump
Pressure
tank
Water
Softener
Taste &
Odor
Filter
Chemical
Feed System
Air Injected
Iron Filter
Water
Neutralizer
Filter
Sediment
Filter
Blending
Tank
HOT
COLD
OUTSIDE
FAUCETS
Water
Heater
INSTALLATION STEPS
IMPORTANT SANITIZING PROCEDURES
Care is taken at the factory to keep your water filter clean and sanitary. Materials used to make the filter will not infect
or contaminate your water supply, and will not cause bacteria to grow. However, during shipping, storage, installing
and operating, bacteria could get into the filter. For this reason, sanitizing as follows is suggested* when installing.
a.
Pour about 1 oz. or 2 oz. of the following disinfectant into the valve
inlet
fitting.
D
Calcium hypochlorite, available in granular or tablet form, under trade names such as Perchloron or HTH
--- OR ---
D
Common 5.25% household bleach (Clorox, Linco, Bo Peep, White Sail, Eagle, etc. brands)
b.
Sanitizing will be continued when you complete step 9 on page 9.
*
Sanitizing is recommended by the Water Quality Association for disinfecting. On some water supplies, they suggest
periodic sanitizing.
1
. INSTALL INCLUDED SINGLE BYPASS VALVE and
/
or INSTALLATION ADAPTORS
NOTE:
All fittings are in the parts bag.
a.
Push the bypass valve, with lubricated o---ring seals in place, into the valve inlet and outlet ports,
Figure 5. Be sure the o---ring sealing surface is clean.
--- AND
/
OR ---
b.
Slide plastic installation adaptors, with lubricated o---ring seals in place, into the filter valve or bypass valve
inlet and outlet ports, Figure 4 and Figure 5. Be sure the o---ring sealing surface is clean.
NOTE:
Be sure the turbine and support are in place in the valve outlet, as shown in Figure 4 and Figure 5.
c.
Snap the two large plastic clips into place, from the top down, Figure 4 and Figure 5. Be sure they snap
into place. Pull on the bypass valve, or installation adaptors, to make sure they are held securely in place.
NOTE:
For lubrication, use silicone grease approved for use on potable water supplies.
2
. TURN OFF WATER SUPPLY
a.
Close the main water supply valve, near well pump or water meter.
b.
Shut off the electricity or fuel supply to the water heater.
c.
Open high and low faucets to drain all water from hose pipes.