background image

15

FACEPLATE TIMER FEATURES, SETTINGS AND SERVICE

service:

RECHARGE CYCLE TIME ADJUSTMENTS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The default settings for backwash (25 minutes) and fast rinse (5 minutes) cycles of recharge are factory set

for maximum performance of the filter. Use the following procedures to check for correct cycle times, or to

change if desired. However, only trained technicians should change the time settings.

NOTE:

Fill and brine times are adjustable, but preset at the factory to zero minutes. It is recommended to leave

these settings as preset, unless the filter is used in a custom application by the installer.

service:

ADJUSTABLE BACKWASH TIME

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Press and hold the Select but-

ton until the display shows

“000--- ---”, then press the Se-

lect button three times to ad-

vance to the Backwash time

adjust screen.

Using the Up or Down buttons

adjust the backwash time

from 0 minutes to 60 minutes.

service:

ADJUSTABLE FAST RINSE TIME

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Press and hold the Select but-

ton until the display shows

“000--- ---”, then press the Se-

lect button four times to ad-

vance to the Fast Rinse time

adjust screen.

Using the Up or Down buttons

adjust the Fast Rinse time

from 0 minutes to 60 minutes.

GENERAL INFORMATION

The air injector adaptor is installed between the filter valve and mineral tank. A pump injects air into the iron

filter through the adaptor. The air oxidizes the iron. The oxidized iron is then mechanically filtered by the filter

mineral bed. The solenoid valve allows excess air to vent from the tank.

SERVICE, BACKWASH AND FAST RINSE CYCLES

SERVICE (See Figure 11):

Unfiltered water enters the valve inlet port. Internal valve porting routes the water

into the mineral tank. The water is filtered as it passes through the mineral bed, then enters the bottom distribu-

tor. Filtered water flows back into the valve and out the valve outlet, to the house filtered water pipes.

In time, the filter needs cleaning to remove sediments, dirt, iron, etc., from the mineral bed. This cleaning is

done in two stages, or cycles, called backwash and fast rinse. It is started automatically by the timer.

BACKWASH (See Figure 12):

The timer starts the valve motor and moves the valve into backwash position.

Water is routed down and out the bottom distributor, up through the mineral bed, and out of the filter to the

drain. The fast flow (controlled by a flow plug in the drain fitting) flushes dirt, sediments, iron deposits, etc.

to the drain. The mineral bed is lifted and expanded for maximum cleaning.

FAST RINSE (See Figure 13):

Valve rotation positions the inner discs so water flow enters the mineral tank

through the top, and exits at the bottom, to the drain. The fast flow of water downward, packs the mineral

bed and prepares it for return to service.

The timer energizes the valve motor again to return the valve to service.

Содержание NS AIIF2

Страница 1: ...d high flow 1 valve MODEL NS AIIF2 Installation D D Operation D D Maintenance D D Repair Parts D D Designed Engineered Assembled in the U S A ECODYNE WATER CONDITIONING 1890 Woodlane Drive Woodbury MN...

Страница 2: ...to you at no cost if our repair department determines it to be defective under the terms of the warranty This warranty gives you specific legal rights and you may have other rights which vary from sta...

Страница 3: ...air If it is backwashed before the air is removed the valve may become plugged with birm particles or particles may be flushed to the drain TABLE OF CONTENTS PAGE NO Warranty Safety Guides 2 Unpackin...

Страница 4: ...al Filter Timer 24V 60 Hz Air Pump 120V 60 Hz Some feed water with high iron concentrations or low pH may require limited service flows or a neutralizer filter be fore the system TABLE 1 pH 6 5 7 0 7...

Страница 5: ...VALVE IN BYPASS AND ADVANCE FILTER VALVE TO BACKWASH BEFORE DISASSEMBLY DRAIN HOSE 5 8 I D minimum to floor drain 5 gal min FIGURE 1 To Outlet Relay Box VENT TUBE 20 ft coil excess tube do not cut To...

Страница 6: ...e joint compound D primer D solvent cement D LEAD FREE solder and flux MATERIALS YOU WILL NEED H bypass valve or 3 valves H pipe and fittings as required H 5 8 I D minimum drain hose either standard g...

Страница 7: ...Water Quality Association for disinfecting On some water supplies they suggest periodic sanitizing 1 INSTALL INCLUDED SINGLE BYPASS VALVE and or INSTALLATION ADAPTORS NOTE All fittings are in the part...

Страница 8: ...tings from the main water pipe or from bypass valves installed in step 3 to the filter inlet and outlet copper tubes BE SURE UNFILTERED WATER SUPPLY PIPE GOES TO THE FILTER INLET SIDE Trace the water...

Страница 9: ...ads NOTE Flexible drain hose is not allowed in all localities See option on page 6 b Route the hose to the drain point standpipe laundry tub floor drain etc as typically shown in Figure 1 Affix the en...

Страница 10: ...orresponding connectors of the wire harness located near the solenoid under the top cover Route the wiring through the clip in the bottom cover as shown in Figure 2 12 CONNECT AIR PUMP a Fasten the ai...

Страница 11: ...TIME OF DAY If the words PRESENT TIME do not show in the display press the SELECT button until they do Press the UP or DOWN buttons to set the present time Up moves the display ahead down moves the t...

Страница 12: ...l fide set the filter to recharge more often than the table above shows Press the SELECT button to set and advance to the next set up screen SET RECHARGE TIME The default setting is 12 00 AM This is a...

Страница 13: ...ater flow has stoped D Make sure the ball valve on the neck adaptor is open See Figure 10 D Make sure the solenoid vent is open when the air pump is running D Make sure the vent tube is held securely...

Страница 14: ...r supply to the filter use the plumbing bypass valve s feature POWER OUTAGE MEMORY If electrical power to the timer is interrupted the memory built into timer circuitry keeps all settings for several...

Страница 15: ...lter through the adaptor The air oxidizes the iron The oxidized iron is then mechanically filtered by the filter mineral bed The solenoid valve allows excess air to vent from the tank SERVICE BACKWASH...

Страница 16: ...16 WATER FLOW PATHS THROUGH VALVE FIGURE 11 SERVICE CYCLE FIGURE 12 BACKWASH CYCLE FLOW PLUG FIGURE 13 FAST RINSE CYCLE...

Страница 17: ...ank This supplies oxygen that aerates the water and oxidizes iron manganese and hydrogen sulfide generating particles The vent solenoid is opened during this time permitting oxygen depleted air to esc...

Страница 18: ...ton to move filter into fast rinse Again look for fast drain flow To return filter to service press the Touch Hold button NOTE While in manual advance the time display will automatically return to the...

Страница 19: ...ay For correct filter operation the model code number must be HAIIF To reset the code press the Up or Down button until the correct number shows 3 Press Select to return the present time display If th...

Страница 20: ...0 11 12 6 5 Valve Assembly see pages 22 23 1 WARNING FILTER TANK CONTAINS AIR TO RELIEVE PRES SURE PUT BYPASS VALVE IN BYPASS AND ADVANCE FILTER VALVE TO BACKWASH BEFORE DISASSEMBLY 26 15 18 17 20 14...

Страница 21: ...9 Tank Base KEY NO PART NO DESCRIPTION 7112963 Distributor O ring Kit includes Key Nos 14 16 14 O ring 13 16 I D x 1 1 16 O D 15 O ring 2 7 8 I D x 3 1 4 O D 16 O ring 2 3 4 I D x 3 O D 17 7310278 Ada...

Страница 22: ...PAIR PARTS 50 51 53 52 54 55 56 57 58 59 60 61 66 67 62 63 64 68 69 75 76 65 80 81 84 85 86 cross section view seal wear strip flow plug assembly assembled view 78 77 73 88 74 79 83 82 82 72 70 71 87...

Страница 23: ...00 Rotor Disc 68 7171187 Plug Drain Seal 69 7129889 Spring 70 7089306 Clip 4 req KEY NO PART NO DESCRIPTION 71 7271204 Installation Adaptor 1 2 req 72 7311127 O ring 1 1 16 x 1 5 16 4 req 7290931 Turb...

Страница 24: ...ECODYNE WATER CONDITIONING 1890 Woodlane Drive Woodbury MN 55125...

Отзывы: