background image

2

WATER FILTER WARRANTY

Warrantor: North Star Water Conditioning, 1890 Woodlane Drive, Woodbury, MN, 55125

Warrantor guarantees, to the original owner, that:

One Year Full Warranty:

D

For a period of one (1) year from the date of purchase, all parts will be free of defects in materials and workmanship, and will perform

their normal functions.

D

For a period of one (1) year from the date of purchase, labor to repair or replace any part deemed to be defective in materials and work-

manship, will be provided at no additional cost.

Limited Warranties:

D

For a period of ten (10) years from the date of purchase, the salt tank and fiberglass mineral tank will not rust, corrode, leak, burst, or

in any other manner, fail to perform their proper functions.

D

For a period of three (3) years from the date of purchase, the electronic control board and valve body will be free of defects in materials

and workmanship, and will perform their normal functions.

If, during such respective period, a part proves to be defective, Warrantor will ship a replacement part, directly to your home, without charge.

After the first year, labor necessary to maintain this product is not covered by the product warranty.

General Conditions

Damage to any part of this water filter because of misuse, misapplication, neglect, alteration, accident, installation or operation contrary

to our printed instructions, or damage caused by any unusual force of nature such as, but not limited to, freezing, flood, hurricane, tornado,

or earthquake is not covered by this warranty. In all such cases, regular parts and service charges will apply.
We assume no warranty liability in connection with this water filter other than specified herein. This warranty is in lieu of all other warranties,

expressed or implied, including warranties of fitness for a particular purpose. We do not authorize any person or representative to assume

for us any other obligations on the sale of this water filter.
Should a defect or malfunction occur, contact your contractor. If you are unable to contact your contractor, return the part, freight prepaid,

directly to the factory at the address below. Enclose with the part a full description of the problem, with your name, full address, date pur-

chased, model and serial numbers, and selling contractor’s name and address. We will repair or replace the part and return it to you at no

cost if our repair department determines it to be defective under the terms of the warranty.
This warranty gives you specific legal rights and you may have other rights which vary from state to state.
This water filter is manufactured by North Star Water Conditioning, 1890 Woodlane Drive, Woodbury, MN, 55125; customer information tele-

phone no. 1--800--972--0135.

SAFETY GUIDES

Follow the installation instructions carefully. Failure to install the filter properly

voids the warranty.

Before you begin installation, read this entire manual. Then obtain all the materials and tools you will need to make the

installation.

Check local plumbing and electrical codes.

The installation must conform to them.

NOTE:

Codes in the state of Massachusetts require installation by a licensed plumber. For installation, use plumbing

code 248---CMR of the Commonwealth of Massachusetts.

Use only lead--free solder and flux

for all sweat-solder connections as required by state and federal codes.

Use care when handling the filter. Do not turn upside down, drop, or set on sharp protrusions.
Do not locate the filter where freezing temperatures occur. Do not attempt to filter water over 120

F.

Freezing, or hot

water damage voids the warranty.

Avoid installing in direct sunlight. Excessive sun heat may cause distortion or other damage to non---metallic parts.
The filter requires a

minimum water flow of 5 gallons per minute

at the inlet for

backwash

.

Recommended maximum allowable inlet water pressure is 80 psi.

Use a pressure reducing valve if necessary. Be

sure the addition of a pressure reducing valve will not reduce the flow to less than the 5 gpm needed for backwash.

This filter controller works on 24 Volt, 60 Hz electrical power only.

Be sure to use the included transformer, and

plug it into a nominal 120V, 60 cycle household outlet that is grounded and properly protected by an over---current de-

vice such as circuit breaker or fuse. The relay box for the air pump must be plugged into a separate 120V grounded

household outlet.
This system is not intended to be used for treating water that is microbiologically unsafe or of unknown quality without

adequate disinfection before or after the system.

European Directive 2002/96/EC requires all electrical and electronic equipment to be disposed of according to

Waste Electrical and Electronic Equipment (WEEE) requirements. This directive or similar laws are in place na-

tionally and can vary from region to region. Please refer to your state and local laws for proper disposal of this

equipment.

Содержание NS AIIF2

Страница 1: ...d high flow 1 valve MODEL NS AIIF2 Installation D D Operation D D Maintenance D D Repair Parts D D Designed Engineered Assembled in the U S A ECODYNE WATER CONDITIONING 1890 Woodlane Drive Woodbury MN...

Страница 2: ...to you at no cost if our repair department determines it to be defective under the terms of the warranty This warranty gives you specific legal rights and you may have other rights which vary from sta...

Страница 3: ...air If it is backwashed before the air is removed the valve may become plugged with birm particles or particles may be flushed to the drain TABLE OF CONTENTS PAGE NO Warranty Safety Guides 2 Unpackin...

Страница 4: ...al Filter Timer 24V 60 Hz Air Pump 120V 60 Hz Some feed water with high iron concentrations or low pH may require limited service flows or a neutralizer filter be fore the system TABLE 1 pH 6 5 7 0 7...

Страница 5: ...VALVE IN BYPASS AND ADVANCE FILTER VALVE TO BACKWASH BEFORE DISASSEMBLY DRAIN HOSE 5 8 I D minimum to floor drain 5 gal min FIGURE 1 To Outlet Relay Box VENT TUBE 20 ft coil excess tube do not cut To...

Страница 6: ...e joint compound D primer D solvent cement D LEAD FREE solder and flux MATERIALS YOU WILL NEED H bypass valve or 3 valves H pipe and fittings as required H 5 8 I D minimum drain hose either standard g...

Страница 7: ...Water Quality Association for disinfecting On some water supplies they suggest periodic sanitizing 1 INSTALL INCLUDED SINGLE BYPASS VALVE and or INSTALLATION ADAPTORS NOTE All fittings are in the part...

Страница 8: ...tings from the main water pipe or from bypass valves installed in step 3 to the filter inlet and outlet copper tubes BE SURE UNFILTERED WATER SUPPLY PIPE GOES TO THE FILTER INLET SIDE Trace the water...

Страница 9: ...ads NOTE Flexible drain hose is not allowed in all localities See option on page 6 b Route the hose to the drain point standpipe laundry tub floor drain etc as typically shown in Figure 1 Affix the en...

Страница 10: ...orresponding connectors of the wire harness located near the solenoid under the top cover Route the wiring through the clip in the bottom cover as shown in Figure 2 12 CONNECT AIR PUMP a Fasten the ai...

Страница 11: ...TIME OF DAY If the words PRESENT TIME do not show in the display press the SELECT button until they do Press the UP or DOWN buttons to set the present time Up moves the display ahead down moves the t...

Страница 12: ...l fide set the filter to recharge more often than the table above shows Press the SELECT button to set and advance to the next set up screen SET RECHARGE TIME The default setting is 12 00 AM This is a...

Страница 13: ...ater flow has stoped D Make sure the ball valve on the neck adaptor is open See Figure 10 D Make sure the solenoid vent is open when the air pump is running D Make sure the vent tube is held securely...

Страница 14: ...r supply to the filter use the plumbing bypass valve s feature POWER OUTAGE MEMORY If electrical power to the timer is interrupted the memory built into timer circuitry keeps all settings for several...

Страница 15: ...lter through the adaptor The air oxidizes the iron The oxidized iron is then mechanically filtered by the filter mineral bed The solenoid valve allows excess air to vent from the tank SERVICE BACKWASH...

Страница 16: ...16 WATER FLOW PATHS THROUGH VALVE FIGURE 11 SERVICE CYCLE FIGURE 12 BACKWASH CYCLE FLOW PLUG FIGURE 13 FAST RINSE CYCLE...

Страница 17: ...ank This supplies oxygen that aerates the water and oxidizes iron manganese and hydrogen sulfide generating particles The vent solenoid is opened during this time permitting oxygen depleted air to esc...

Страница 18: ...ton to move filter into fast rinse Again look for fast drain flow To return filter to service press the Touch Hold button NOTE While in manual advance the time display will automatically return to the...

Страница 19: ...ay For correct filter operation the model code number must be HAIIF To reset the code press the Up or Down button until the correct number shows 3 Press Select to return the present time display If th...

Страница 20: ...0 11 12 6 5 Valve Assembly see pages 22 23 1 WARNING FILTER TANK CONTAINS AIR TO RELIEVE PRES SURE PUT BYPASS VALVE IN BYPASS AND ADVANCE FILTER VALVE TO BACKWASH BEFORE DISASSEMBLY 26 15 18 17 20 14...

Страница 21: ...9 Tank Base KEY NO PART NO DESCRIPTION 7112963 Distributor O ring Kit includes Key Nos 14 16 14 O ring 13 16 I D x 1 1 16 O D 15 O ring 2 7 8 I D x 3 1 4 O D 16 O ring 2 3 4 I D x 3 O D 17 7310278 Ada...

Страница 22: ...PAIR PARTS 50 51 53 52 54 55 56 57 58 59 60 61 66 67 62 63 64 68 69 75 76 65 80 81 84 85 86 cross section view seal wear strip flow plug assembly assembled view 78 77 73 88 74 79 83 82 82 72 70 71 87...

Страница 23: ...00 Rotor Disc 68 7171187 Plug Drain Seal 69 7129889 Spring 70 7089306 Clip 4 req KEY NO PART NO DESCRIPTION 71 7271204 Installation Adaptor 1 2 req 72 7311127 O ring 1 1 16 x 1 5 16 4 req 7290931 Turb...

Страница 24: ...ECODYNE WATER CONDITIONING 1890 Woodlane Drive Woodbury MN 55125...