background image

14

FACEPLATE TIMER FEATURES, SETTINGS AND SERVICE

NORMAL OPERATION, TIMER DISPLAYS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

During normal operation, the

present time of day, and AM or

PM, show in the time display

area. When a recharge be-

gins,

RECHARGE NOW

starts

to flash in the display, along

with the present time of day.

RECHARGE NOW

flashes un-

til the recharge is over.

feature:

RECHARGE NOW

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

For times you expect to use

more water than usual, use the

RECHARGE NOW control.

Press the Touch---Hold button

until

RECHARGE NOW

begins

to flash in the time display. A

recharge begins immediately. The filter begins to fil-

ter your water again in about 2 hours.

NOTE:

Avoid using HOT water during the recharge,

because the water heater will refill with unfiltered wa-

ter.

feature:

VACATION CONTROL

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Before going on vacation, or

other long absence, press (do

not hold in) the Touch---Hold

button so

VAC

starts to flash in

the display. The timer contin-

ues to keep time, but recharges will not occur and

waste water.

When you return,

press the Touch---Hold button

again to return the filter to service, and the present

time in the display. REMEMBER TO DO THIS, or the

filter will not recharge until you do.

NOTE:

To shut off the water supply to the filter, use

the plumbing bypass valve(s).

feature:

POWER OUTAGE MEMORY

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

If electrical power to the timer is interrupted, the

“memory” built into timer circuitry keeps

all

settings

for several hours. The display is blank and the filter

will not recharge. When electrical power comes on,

one of two things will happen.

1.

The present time of day will show, meaning the

timer memory has kept all time settings.

NOTE:

If the filter was recharging when power was

lost, it will now finish the cycle.

2.

The display will show a time, but it will be flashing.

The timer memory did

not

keep the time settings and

they must be reset (page 11). The display returns to

a flashing time, then begins to keep time again. If you

do not reset the time of day, the filter will recharge

based on the days to recharge, however, recharges

will most likely be at the wrong time of day.

NOTE: The flashing display is to remind you to re-

set the timer.

If the filter was recharging when power was lost, the

valve will return to service position without finishing

the cycle. Use RECHARGE NOW (see above) to

start another cycle if needed.

feature:

ERROR CODES

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

An error code could appear in

the faceplate display if a prob-

lem occurs in the filter. If you

see an error code, for example

Err03, instead of the present time of day, please call

your local dealer for service, or see your warranty on

page 2.

Содержание NS AIIF2

Страница 1: ...d high flow 1 valve MODEL NS AIIF2 Installation D D Operation D D Maintenance D D Repair Parts D D Designed Engineered Assembled in the U S A ECODYNE WATER CONDITIONING 1890 Woodlane Drive Woodbury MN...

Страница 2: ...to you at no cost if our repair department determines it to be defective under the terms of the warranty This warranty gives you specific legal rights and you may have other rights which vary from sta...

Страница 3: ...air If it is backwashed before the air is removed the valve may become plugged with birm particles or particles may be flushed to the drain TABLE OF CONTENTS PAGE NO Warranty Safety Guides 2 Unpackin...

Страница 4: ...al Filter Timer 24V 60 Hz Air Pump 120V 60 Hz Some feed water with high iron concentrations or low pH may require limited service flows or a neutralizer filter be fore the system TABLE 1 pH 6 5 7 0 7...

Страница 5: ...VALVE IN BYPASS AND ADVANCE FILTER VALVE TO BACKWASH BEFORE DISASSEMBLY DRAIN HOSE 5 8 I D minimum to floor drain 5 gal min FIGURE 1 To Outlet Relay Box VENT TUBE 20 ft coil excess tube do not cut To...

Страница 6: ...e joint compound D primer D solvent cement D LEAD FREE solder and flux MATERIALS YOU WILL NEED H bypass valve or 3 valves H pipe and fittings as required H 5 8 I D minimum drain hose either standard g...

Страница 7: ...Water Quality Association for disinfecting On some water supplies they suggest periodic sanitizing 1 INSTALL INCLUDED SINGLE BYPASS VALVE and or INSTALLATION ADAPTORS NOTE All fittings are in the part...

Страница 8: ...tings from the main water pipe or from bypass valves installed in step 3 to the filter inlet and outlet copper tubes BE SURE UNFILTERED WATER SUPPLY PIPE GOES TO THE FILTER INLET SIDE Trace the water...

Страница 9: ...ads NOTE Flexible drain hose is not allowed in all localities See option on page 6 b Route the hose to the drain point standpipe laundry tub floor drain etc as typically shown in Figure 1 Affix the en...

Страница 10: ...orresponding connectors of the wire harness located near the solenoid under the top cover Route the wiring through the clip in the bottom cover as shown in Figure 2 12 CONNECT AIR PUMP a Fasten the ai...

Страница 11: ...TIME OF DAY If the words PRESENT TIME do not show in the display press the SELECT button until they do Press the UP or DOWN buttons to set the present time Up moves the display ahead down moves the t...

Страница 12: ...l fide set the filter to recharge more often than the table above shows Press the SELECT button to set and advance to the next set up screen SET RECHARGE TIME The default setting is 12 00 AM This is a...

Страница 13: ...ater flow has stoped D Make sure the ball valve on the neck adaptor is open See Figure 10 D Make sure the solenoid vent is open when the air pump is running D Make sure the vent tube is held securely...

Страница 14: ...r supply to the filter use the plumbing bypass valve s feature POWER OUTAGE MEMORY If electrical power to the timer is interrupted the memory built into timer circuitry keeps all settings for several...

Страница 15: ...lter through the adaptor The air oxidizes the iron The oxidized iron is then mechanically filtered by the filter mineral bed The solenoid valve allows excess air to vent from the tank SERVICE BACKWASH...

Страница 16: ...16 WATER FLOW PATHS THROUGH VALVE FIGURE 11 SERVICE CYCLE FIGURE 12 BACKWASH CYCLE FLOW PLUG FIGURE 13 FAST RINSE CYCLE...

Страница 17: ...ank This supplies oxygen that aerates the water and oxidizes iron manganese and hydrogen sulfide generating particles The vent solenoid is opened during this time permitting oxygen depleted air to esc...

Страница 18: ...ton to move filter into fast rinse Again look for fast drain flow To return filter to service press the Touch Hold button NOTE While in manual advance the time display will automatically return to the...

Страница 19: ...ay For correct filter operation the model code number must be HAIIF To reset the code press the Up or Down button until the correct number shows 3 Press Select to return the present time display If th...

Страница 20: ...0 11 12 6 5 Valve Assembly see pages 22 23 1 WARNING FILTER TANK CONTAINS AIR TO RELIEVE PRES SURE PUT BYPASS VALVE IN BYPASS AND ADVANCE FILTER VALVE TO BACKWASH BEFORE DISASSEMBLY 26 15 18 17 20 14...

Страница 21: ...9 Tank Base KEY NO PART NO DESCRIPTION 7112963 Distributor O ring Kit includes Key Nos 14 16 14 O ring 13 16 I D x 1 1 16 O D 15 O ring 2 7 8 I D x 3 1 4 O D 16 O ring 2 3 4 I D x 3 O D 17 7310278 Ada...

Страница 22: ...PAIR PARTS 50 51 53 52 54 55 56 57 58 59 60 61 66 67 62 63 64 68 69 75 76 65 80 81 84 85 86 cross section view seal wear strip flow plug assembly assembled view 78 77 73 88 74 79 83 82 82 72 70 71 87...

Страница 23: ...00 Rotor Disc 68 7171187 Plug Drain Seal 69 7129889 Spring 70 7089306 Clip 4 req KEY NO PART NO DESCRIPTION 71 7271204 Installation Adaptor 1 2 req 72 7311127 O ring 1 1 16 x 1 5 16 4 req 7290931 Turb...

Страница 24: ...ECODYNE WATER CONDITIONING 1890 Woodlane Drive Woodbury MN 55125...

Отзывы: