PROGRAMMING THE FACEPLATE TIMER
FIGURE 9
UP button
display
DOWN button
SELECT button
TOUCH--HOLD
button
"
TIMER SETTINGS REQUIRED,
upon installation, and after an extended power outage, see Power Outage
Memory, page 14.
When the transformer is plugged into the electrical outlet, the model code and a test number (example: J1.1),
begins to flash in the faceplate display. Then, 12:00 PM and PRESENT TIME begins to flash. Program the timer
as follows.
"
SET PRESENT TIME OF DAY
If the words
PRESENT TIME
do not show in the display, press the
SELECT button until they do.
Press the
UP or
DOWN buttons to set the present time. Up moves the display ahead; down moves
the time backward. Be sure AM or PM, is correct.
Press buttons and quickly release to slowly advance the display. Hold for fast advance. This procedure applies
for all following settings.
Press the
SELECT button to set present time and advance to the next set up screen.
"
SET DAYS TO RECHARGE
The default setting is 3 days. This means the filter will recharge every 3 days. If a change is needed, use the
UP or