Eco Pacific/Super Star- Installation and Service Instructions 20173
4
Table 2: Dimensions (mm), refer Figure 1, 2 and 6
Dimensions / Model
→
↓
SS512
SS516 and
HB416
SS520 and
HB420
SS525
SS530
A- Width
360
360
437
585
585
B- Depth/Length
1160
1160
1160
1160
1160
C- Height
450
450
450
450
450
D- Flue Collar, mm
100
100
100
100
100
E- Duct Connections
Return/Supply
300x300
300x300
300x300
350x350
350x350
Extra
Air
panel
collars
NA
NA
350x350
400x400
400x400
General Requirements
The installation of this appliance must conform to the following requirements:
1.
These installation instructions.
2.
The Australian Gas Association Code, AS5601 (old AG601) for installation
3.
Local gas fitting regulations.
4.
Local building regulations.
5.
Local electrical supply authority regulations.
6. Fit dedicated circuit breakers in the power line of the heater in the meter box.
Important Notes
Only licensed/AUTHORIZED PERSONNEL
must install this appliance and must carry out
likewise servicing of this unit.
Please note that the manufacturers reserve the right to refuse to attend the warranty service to
the unit if the unit is not installed according to the above requirements and if adequate safety and
accessibility to the unit is not provided on site with stipulated clearances.
Inspection
As soon as a unit is received it should be inspected for any damage that may have occurred
during transit. If any damage is evident it should be noted on the
carrier’s freight bill with
evidence.
Location
The Super Star is an internal/external air heater, designed for installation in either a roof space, or
in the space underneath a floor, or external to the house- if it is an external unit, with connection
to a warm air heating duct-system. Refer to Table 2 for general dimensions. Although the
location is usually predetermined please check with the owner’s or dealer’s installation plans. If a
location has not been decided, consideration must be given to the following:
1. The location must provide adequate structural support; space for service access; and
clearances for return and supply air duct connections.
2. Care should be taken to locate the unit and ductwork so that the supply air does not short
circuit to the return air.