11
RECOMMENDATION
- Mains cable should be hidden under one of the channels in the bottom of the product, see pt. 3.5.6.
- Always follow local codes or CSA C22.1 Canadian Electrical Code.
3.6.3 Torque settings
3.6.4 Fitting instructions
3.6.5 Fitting recommendation
!
WARNING
!
The product must be completely filled with water before the power is switched on.
Do not remove the junction box cover until the power supply to the product is switched OFF.
Do not attempt to repair or replace any electrical component installed in the product before the
power supply is switched OFF.
Do not use the product with a voltage other than what is specified on the product data plate.
Do not connect the power supply wiring to anywhere other than the product’s main power
connection. DO NOT bypass the safety thermostat.
!
CAUTION
!
The product must have a clearance for servicing of minimum 40 cm in front of the junc-
tion box cover and sufficient space for servicing above the top.
Component
Torque
5/4” heating element
60 Nm (+/- 5)
Thermostat screws
2 Nm (+/- 0.1)
Screw on the element head 2 Nm (+/- 0.1)