background image

15

7.1  Customer service

In case of problems that cannot be resolved 
with the aid of the troubleshooting guide in this 
installation manual, contact either:
A) The installer who supplied the product. 
B)  King  Heating Products: hello@kingheating-

products.com.

7. WARRANTY CONDITIONS

1. Scope

King Heating Products (hereinafter called KHP) warrants for 2 

years from the date of purchase, that the Product will: i) conform 

to  KHP  specification,  ii)  be  free  from  defects  in  materials  and 

workmanship, subject to conditions below. All components carry 

a 2-year warranty. 

The warranty is voluntarily extended by KHP to 5 years for the 

stainless steel inner tank. This extended warranty only applies 

to Products purchased by a consumer, that has been installed 

for  private  use  and  that  has  been  distributed  by  KHP  or  by  a 

distributor where the Products have been originally sold by KHP.

The extended warranty does not apply to Products purchased by 

commercial entities or for Products that have been installed for 

commercial use. These shall be subject only to the mandatory 

provisions of the law. The conditions and limitations set out below 

shall apply.

2. Coverage

If a defect arises and a valid claim is received within the statutory 

warranty period, at its option and to the extent permitted by law, 

KHP shall either; i) repair the defect, or; ii) replace the product with 

a product that is identical or similar in function, or; iii) refund the 

purchase price.

If a defect arises and a valid claim is received after the statutory 

warranty period has expired, but within the extended warranty 

period, KHP will supply a product that is identical or similar in 

function. KHP will in such cases not cover any other associated 

costs. 

Any  exchanged  Product  or  component  will  become  the  legal 

property of KHP. Any valid claim or service does not extend the 

original warranty. The replacement Product or part does not carry 

a new warranty.

3. Conditions

The Product is manufactured to suit most public water supplies. 

However,  there  are  certain  water  chemistries  (outlined  below) 

that  can  have  a  detrimental  effect  on  the  Product  and  its  life 

expectancy. If there are uncertainties regarding water quality, the 

local water supply authority can supply the necessary data.

The warranty applies only if the conditions set out below are met 

in full:

• 

The Product has been installed by a professional installer, 

in accordance with the instructions in the installation 

manual and all relevant Codes of Practice and Regulations 

in force at the time of installation.

• 

The Product has not been modified in any way, tampered 

with or subjected to misuse and no factory fitted parts have 

been removed for unauthorized repair or replacement. 

• 

The Product has only been connected to a domestic mains 

water supply in compliance with the European Drinking 

Water Directive EN 98/83 EC, or latest version. The water 

should  not  be  aggressive,  i.e.  the  water  chemistry  shall 

comply with the following:

 

- Chloride 

< 250 mg / L

 

- Electric Conductivity (EC) @25°C 

< 750 uS / cm

 

- Saturation Index (LSI) @80°C 

> - 1,0 / < 0,8

 

- pH level 

> 6,0 / < 9,5

• 

The immersion heater has not been exposed to hardness 

levels  exceeding  10°dH  (180  ppm  CaCO3).  A  water 

softener is recommended in such cases.

• 

Any  disinfection  has  been  carried  out  without  affecting 

the Product in any way whatsoever. The Product shall be 

isolated from any system chlorination.

• 

The  Product  has  been  in  regular  use  from  the  date  of 

installation. If the Product is not intended to be used for 60 

days or more, it must be drained.

• 

Service  and/or  repair  shall  be  done  according  to  the 

installation manual and all relevant codes of practice. Any 

replacement parts used shall be original KHP spare parts. 

• 

Any third-party costs associated with any claim has been 

authorized in advance by KHP in writing. 

• 

The purchase invoice and/or installation invoice, a water 

sample as well as the defective product is made available 

to KHP upon request. 

Failure to follow these instructions and conditions may result in 

product failure, and water escaping from the Product.

4. Limitations

The warranty does not cover:

• 

Any  fault  or  costs  arising  from  incorrect  installation, 

incorrect application, lack of regular maintenance 

in accordance with the installation manual, neglect, 

accidental or malicious damage, misuse, any alteration, 

tampering or repair carried out by a non-professional, any 

fault arising from the tampering with or removal of any 

factory fitted safety components or measures.

• 

Any consequential damage or any indirect loss caused by 

any failure or malfunction of the Product whatsoever.

• 

Any pipework or any equipment connected to the Product.

• 

The  effects  of  frost,  lightning,  voltage  variation,  lack 

of  water,  dry  boiling,  excess  pressure  or  chlorination 

procedures.

• 

The effects of stagnant (de-aerated) water if the Product 

has been left unused for more than 60 days consecutively. 

• 

Damage caused during transportation. Buyer shall give the 

carrier notice of such damage.

• 

Costs arising if the Product is not immediately accessible 

for servicing.

These warranties do not affect the Buyer’s statutory rights.

8. REMOVING THE PRODUCT

8.1  Removal

A) Disconnect the power supply.
B) Shut off incoming cold water supply.
C) Empty the product of water – see pt. 4.4.
D) Disconnect all pipes.
E)  The product can now be removed.

8.2 Returns scheme

This product is recyclable and should be taken 
to the environmental recycling centre. If the 
product is to be replaced with a new one, the 
installer should be able to take the old cylinder 
away for recycling.

Содержание Saga - S 200 - 3 kW

Страница 1: ...ga S 200 300 l EN FR SAFETY INFORMATION O M INFORMATION INSTALLATION MANUAL TDS TECHNICAL DATA SHEET INFORMATIONS DE S CURIT INFORMATIONS FDV INSTRUCTIONS DE MONTAGE FT FICHE TECHNIQUE 145918 01 04 20...

Страница 2: ...damage may result if the product is not installed or used in the intended manner Keep this manual and other relevant doc uments where they are accessible for fu ture reference The manufacturer assume...

Страница 3: ...r if it has been damaged or dropped This water heater should be serviced only by qualified service personnel Contact nearest authorized service facility for examination repair or adjustment IF YOU SME...

Страница 4: ...witched on Maintenance settings should only be carried out by persons over 18 years of age with sufficient understanding The water heater can make water hot enough to cause severe burns instantly whic...

Страница 5: ...orking environment ISO 45001 2 2 Intended use The Saga series is designed to supply homes with hot running water 2 3 Compliance The product complies with standards for Low voltage LVD 2014 35 EU Elect...

Страница 6: ...ent 9 1 Drain valve factory fitted 10 3 Feet factory fitted A D B C E 5 2 3 4 1 6 9 7 8 10 All dimensions in mm 3 3 1 Risks during installation and maintenance Electric shock risk Contact with electri...

Страница 7: ...e placed in a room with drain to avoid any material damage in case of leakage Liability for consequential damage will only apply if this is followed The product should be placed in a dry and permanent...

Страница 8: ...et outlet combination to the desired position Tighten compression fitting to the cylin der see 3 5 4 B CW and HW pipes of a suitable size and quality should be led to the inlet outlet combination and...

Страница 9: ...le material damage 3 5 5 Fitting instructions 3 5 6 Installation recommendation CAUTION The product should be placed in a room with drain to avoid any material damage in case of leakage Liability for...

Страница 10: ...e connected to a sepa rate fuse branch circuit or to a suitable wall socket For permanently connection the screw terminals L1 and L2 can be wired in the field PROVIDED THAT a trained field technician...

Страница 11: ...tched OFF Do not attempt to repair or replace any electrical component installed in the product before the power supply is switched OFF Do not use the product with a voltage other than what is specifi...

Страница 12: ...the maximum and leave open prevents vacuum D Remove the cover at the drain valve 2 by loosening the screw 5 F Connect a hose to the nozzle on the drain valve Place the other end of the hose out side i...

Страница 13: ...nt in the junction box Before any electrical work is done the power supply must be disconnected and secured against activation while the work is in progress WARNING Increasing the water temperature in...

Страница 14: ...t heating element Contact authorized installer No hot water Power supply interrupted Verify that the fuse is on the earth breaker has not tripped Thermostat has cut out Press the RESET button on the s...

Страница 15: ...d for unauthorized repair or replacement TheProducthasonlybeenconnectedtoadomesticmains water supply in compliance with the European Drinking Water Directive EN 98 83 EC or latest version The water sh...

Страница 16: ...eur et ne peuvent pas tre reproduites ni distribu es sans le consentement crit pr alable du fabricant Sous r serve de modifications Manufactured by OSO Hotwater AS Industriveien 1 3300 Hokksund Norway...

Страница 17: ...Saga S 200 300 l FR INFORMATIONS DE S CURIT INFORMATIONS FDV INSTRUCTIONS DE MONTAGE FT FICHE TECHNIQUE 145918 01 04 2020...

Страница 18: ...utilis comme il se doit Pour toute r f rence ult rieure conservez ce manuel ainsi que les autres documents perti nents dans un endroit facilement accessible Le fabricant part du principe que l utilisa...

Страница 19: ...VOUS SENTEZ DE LA FUM E teignez imm diatement l alimentation du chauffe eau Si la fum e persiste apr s l arr t de l alimentation contactez votre service incendie local Lorsque la fum e s est arr t e...

Страница 20: ...en les r glages doivent tre effectu s uniquement par des personnes de plus de 18 ans et aptes comprendre Le chauffe eau peut rendre l eau suffisamment chaude pour causer des br lures graves instanta n...

Страница 21: ...ion conforme l usage pr vu La s rie Saga est con ue pour approvisionner les foyers en eau courante chaude 2 3 Conformit Le produit est conforme aux normes de Basse tension LVD 2014 35 UE Compatibilit...

Страница 22: ...ieds mont s en usine A D B C E 5 2 3 4 1 6 9 7 8 10 Dimensions en mm 3 3 1 Risques lors de l installation et de l entretien Risque d lectrocution Le contact avec des pi ces lectriques peut entra ner d...

Страница 23: ...oduit doit tre plac dans une pi ce quip e d une vacuation pour viter tout dommage mat riel en cas de fuite La responsabilit pour tout dommage cons cutif ne s appliquera que lorsque ces conditions sont...

Страница 24: ...ntr e de sortie sur la position d sir e Resserrer le raccordement de compres sion au cylindre voir 3 5 4 B Des tuyaux EF et EC de taille et de qualit appropri es doivent tre conduits la com binaison d...

Страница 25: ...mat riels 3 5 5 Instructions de raccordement 3 5 6 Recommandation d installation AVERTISSEMENT Le produit doit tre plac dans une pi ce quip e d une vacuation pour viter tout dommage mat riel en cas de...

Страница 26: ...lectrique ou une prise murale adapt e Pour une connexion permanente les bornes vis L1 et L2 peuvent tre c bl es sur site condition qu un technicien de terrain qualifi soit impliqu pour s assurer que l...

Страница 27: ...duit soit sur OFF N essayez pas de r parer ou de remplacer tout composant lectrique install dans le produit avant que l alimentation soit sur OFF N utilisez pas le produit avec une tension autre que c...

Страница 28: ...ration D Retirez le couvercle du robinet de vidange 2 en desserrant la vis 5 F Connectez un tuyau la buse du robinet de vidange Placez l autre extr mit du tuyau l ext rieur dans une vacuation ou dans...

Страница 29: ...Avant d effectuer un travail lectrique l alimentation doit tre d bran ch e et s curis e pour ne pas s activer pen dant que les travaux sont en cours ATTENTION Augmenter la temp rature de l eau dans le...

Страница 30: ...pue V rifiez que le fusible est allum le disjoncteur ne s est pas d clench Le thermostat s est coup Appuyez sur le bouton RESET sur le thermos tat de s curit voir Guide de l utilisateur L l ment chau...

Страница 31: ...placement non autoris s Le produit n a t raccord qu un r seau d eau potable conforme la directive europ enne sur l eau destin e la consommation humaine EN 98 83 CE ou sa version la plus r cente L eau...

Страница 32: ...eur et ne peuvent pas tre reproduites ni distribu es sans le consentement crit pr alable du fabricant Sous r serve de modifications Manufactured by OSO Hotwater AS Industriveien 1 3300 Hokksund Norway...

Отзывы: