background image

TROUBLESHOOTING CHECKLIST (Caution: shut off power to pump)

PROBLEMS

PUMP DOES NOT RUN  

AND MAKES HUMMING 

SOUND 

 

 

 

 

PUMP RUNS BUT DOES  

NOT DELIVER WATER 

 

 

 

 

PUMP RUNS AND 

PUMPS 

OUT SUMP, BUT DOES  

NOT STOP

PUMP RUNS BUT ONLY 

DELIVERS A SMALL  

AMOUNT OF WATER 

 

 

 

 

FUSE BLOWS OR 

CIRCUIT BREAKER 

TRIPS WHEN 

PUMP STARTS 

 

 

 

MOTOR RUNS FOR A  

SHORT TIME, THEN 

STOPS

POSSIBLE CAUSES/SOLUTIONS

•  Line circuit breaker is off, or fuse is blown or loose 

•  Water level in sump has not reached turn-on level as indicated in  

 

  installation drawing. 

•  Pump cord is not making contact in receptacle. 

•  Float is stuck. It should operate freely in basin. 

•  If all of the above are OK, then the motor could be malfunctioning. 

•  Check if valve is installed backwards.  

 

 

 

 

  Arrow on valve should point direction of flow 

•  Discharge shut-off valve (if used) may be closed. 

•  Impeller or volute openings are fully or partially clogged. 

  Remove pump and clean. 

•  Pump is air-locked. Start and stop several times by plugging and  

 

  unplugging cord. Check for clogged vent hole in pump case.  

•  Inlet holes in pump base are clogged. Remove pump and clean the    

  openings. 

•  Vertical pumping distance is too high. Reduce distance or change the  

  discharge fittings of the pump. 

•  Float is stuck in up position. Be sure float operates freely in basin. 

•  Defective float switch. Replace float switch. 

 

 

 

•  Pump is air-locked. Start and stop several times by plugging in and    

  unplugging cord. Check for clogged vent hole in pump case. 

•  Vertical pumping distance is too high. Reduce distance or change the  

  discharge fitting of the pump. Inlet holes in pump base are clogged. 

  Remove pump and clean the strainer and openings. 

•  Impeller or volute openings are fully or partially clogged. 

  Remove pump and clean. 

•  Pump impeller is partially clogged with tar or paint, causing motor to   

  run slow and overload. Remove pump and clean. 

 

 
•  Pump impeller is partially clogged causing motor to run slow and  

 

  overload. Remove pump and clean. 

•  Motor stator may be defective. 

 

•  Fuse size or circuit breaker may be too small. (must be 15 amps). 

•  Impeller or volute opening are fully or partially clogged.

  Remove pump and clean .  

 

•  Inlet holes in pump base are clogged. Remove pump and clean the    

  openings. 

•  Pump impeller is partially clogged causing motor to run slow and  

 

  overload. Remove pump and clean. 

•  Motor stator may be defective. 

•  Impeller or volute openings are fully or partially clogged. 

  Remove pump and clean. Also clean the strainer if one is installed.

 

6  

For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561

ELECTRICAL PRECAUTIONS

 

  Before servicing a pump, always shut off the main power breaker and  

 

  then unplug the pump. Make sure you are not standing in water and are 

wearing insulated protective sole shoes, under flooded conditions. Contact your local electric 

company or a qualified licensed electrician for disconnecting electrical service prior to pump 

removal

Содержание ESE40W

Страница 1: ...Owner s Manual ESE Series Cast Iron Sewage Pumps General Safety 2 Specifications 3 Installation 4 5 Troubleshooting 6 Repair Parts 7 Warranty 8 TABLE OF CONTENTS...

Страница 2: ...avoided will result in death or serious injury Indicates a hazard which if not avoided could result in death or serious injury Indicates a hazard which if not avoided could result in minor or moderate...

Страница 3: ...struction Impeller Length Pumped ESE40M 4 10 115 1 11 0 6600 26 Cast Iron Thermoplastic 20 2 ESE40W 4 10 115 1 11 0 6600 26 Cast Iron Thermoplastic 20 2 ESE50M 1 2 115 1 12 0 7800 27 Cast Iron Thermop...

Страница 4: ...nd or severe damage to pump and will void the warranty a Using an extension cord b Cutting off the ground pin or using an adapter fitting c Working on pump or switch while plugged in d Removing motor...

Страница 5: ...emoval of the pump The remainder of the discharge line should be as short as possible with a minimum of turns to minimize friction head loss Do not restrict the discharge to sizes below 2 Sewage and e...

Страница 6: ...tart and stop several times by plugging in and unplugging cord Check for clogged vent hole in pump case Vertical pumping distance is too high Reduce distance or change the discharge fitting of the pum...

Страница 7: ...any alleged defect Manufacturer will subsequently take corrective action as promptly as reasonably possible No requests for service will be accepted if received more than 30 days after the warranty ex...