INSTALLATION

ELECTRICAL WIRE CONNECTION

OVERLOAD PROTECTION

       

 

Do not work on pump until    

       

 

power is unplugged. 

       

 

Do not cut off ground pin or   

       

 

use an adapter fitting. 

Do not use an extension cord.   

 

 

The pump power cord should be connected to a 

separately fused, grounded line with a minimum  

capacity of 15 amps. It can be connected to non-

fuse breaker at the recommended amperes. 
1. Before installing or servicing this pump, be    

  certain pump’s power source is disconnected. 

2. Installation and electrical wiring must adhere  

  to state and local codes and must be   

 

  completed before priming pump. Check  

 

  appropriate community agencies, or contact   

  local electrical and pump professionals. 

3. Call an electrician when in doubt. Pump  

 

  should be connected to a separate 15  

 

  amp circuit breaker or 15 amp fuse block.    
Note that plugging into existing outlets may    

cause low voltage at motor. This could cause    

blown fuses, tripping of motor overload or  

 

burned out motor. 
4. A permanent ground connection from pump    

  to the grounding bar at the service panel is    

  mandatory. These sump pumps come with a   

  grounding conductor and a grounding-type   

  attachment plug. Do not connect pump to    

  a power supply until permanently grounded.   
For maximum safety, connect pump to a circuit  

equipped with a fault interrupter device when  

positioning the pump’s grounding wire. 

5. Voltage of power supply must match the    

  voltage of the pump.  

6. Before installing pump, clear sump basin of   

  any water, debris or sediment.   

 

 

       

 

Sump basin must be vented 

       

 

in accordance with local 

plumbing codes. These Sump pumps are not  

designed for and CANNOT be installed in loca-

tions classified as hazardous.   
7.  The following may cause injury and/or severe  

  damage to pump and will void the warranty. 

   (a) Using an extension cord. 

 

(b) Cutting off the ground pin or using an    

       adapter fitting. 

  (c) Working on pump or switch while  

    plugged in.

  (d) Removing motor housing, unscrewing    

    impeller, or otherwise removing impeller seal. 

  (e) Running the pump continuously. 

  (f)  Pumping chemicals or corrosive liquids. 

  (g) Pumping gasoline or other flammable liquids 
8. Plastic PVC pipe can be installed in the  

 

  outlet piping. Drain hose, galvanized steel    

  or copper pipe may be used if desired.  

 

  All piping must be clean and free of all  

 

  foreign matter to prevent clogging. 

9. Pump will be inadequate if suspension  

 

  liquids contain solid particles larger than 2”. 

     

   

Verify that the voltage and    

     

   

frequency of the pump shown 

on the nameplate corresponds to those available on 

the mains. The installer must make sure that the  

electric system is grounded in accordance with code. 
•  For outdoor use it is necessary to use cable with  

  a length of  at least 8’. The plug and connection  

  should be protected from water splashes. Before  

  using the pump, always inspect it visually  

 

  (especially power cable and plug) 

•  Do not use pump if it is damaged 

•  If the pump is damaged, have it inspected by an  

  authorized service center. 

•   Make sure that electric connections are protected  

  from flooding. Protect the plug and the power   

  cable from heat or sharp edges. 

    

     

   

The power cable must be 

     

   

replaced by qualified personnel 

only. Grounding: The plug of the power cable has a 

double grounding contact, so that grounding can be 

performed by simply inserting  the plug. 

This pump series has a built in thermal protection 

switch. The pump stops if an overload condition  

occurs. The motor restarts automatically after it has 

cooled down. If it doesn’t start automatically, unplug 

the pump and plug it back in.

4

For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561

Entry pipe

Содержание ESE40W

Страница 1: ...Owner s Manual ESE Series Cast Iron Sewage Pumps General Safety 2 Specifications 3 Installation 4 5 Troubleshooting 6 Repair Parts 7 Warranty 8 TABLE OF CONTENTS...

Страница 2: ...avoided will result in death or serious injury Indicates a hazard which if not avoided could result in death or serious injury Indicates a hazard which if not avoided could result in minor or moderate...

Страница 3: ...struction Impeller Length Pumped ESE40M 4 10 115 1 11 0 6600 26 Cast Iron Thermoplastic 20 2 ESE40W 4 10 115 1 11 0 6600 26 Cast Iron Thermoplastic 20 2 ESE50M 1 2 115 1 12 0 7800 27 Cast Iron Thermop...

Страница 4: ...nd or severe damage to pump and will void the warranty a Using an extension cord b Cutting off the ground pin or using an adapter fitting c Working on pump or switch while plugged in d Removing motor...

Страница 5: ...emoval of the pump The remainder of the discharge line should be as short as possible with a minimum of turns to minimize friction head loss Do not restrict the discharge to sizes below 2 Sewage and e...

Страница 6: ...tart and stop several times by plugging in and unplugging cord Check for clogged vent hole in pump case Vertical pumping distance is too high Reduce distance or change the discharge fitting of the pum...

Страница 7: ...any alleged defect Manufacturer will subsequently take corrective action as promptly as reasonably possible No requests for service will be accepted if received more than 30 days after the warranty ex...

Отзывы: