background image

3

For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561

APPLICATIONS

Ideal for Below Grade Toilets, Laundry Facilities and for Use at Construction Sites.

SPECIFICATIONS & PERFORMANCE

 

 

    

  

 

 

 

 

 

   

 

 

    

Capacity    

 

 

Cord 

Solids 

Model 

HP 

Volt 

Ph 

Amps 

(GPH at 0’)   Max Head 

Construction 

Impeller 

Length 

Pumped 

ESE40M 

4/10  115 

11.0 

6600 

 

26’ 

Cast Iron 

Thermoplastic 

20’ 

2” 

ESE40W 

4/10 

115 

11.0 

6600 

 

26’ 

Cast Iron 

Thermoplastic 20’ 

2”

ESE50M 

1/2 

115 

12.0 

7800 

 

27’ 

Cast Iron 

Thermoplastic 

20’ 

2” 

ESE50W 

1/2 

115 

12.0 

7800 

 

27’ 

Cast Iron 

Thermoplastic 

20’ 

2”

ESE60M 

6/10  115 

12.0 

9910 

 

26’ 

Cast Iron 

Thermoplastic 

20’ 

2”

ESE60W 

6/10  115 

12.0 

9910 

 

26’ 

Cast Iron 

Thermoplastic 

20’ 

2” 

281.8 [11.10]

212[8.35]

2"NPT

49.9 [1.97

]

138.8 [5.47]

380.4 [14.99

]

137.4 [5.41]

Содержание ESE40W

Страница 1: ...Owner s Manual ESE Series Cast Iron Sewage Pumps General Safety 2 Specifications 3 Installation 4 5 Troubleshooting 6 Repair Parts 7 Warranty 8 TABLE OF CONTENTS...

Страница 2: ...avoided will result in death or serious injury Indicates a hazard which if not avoided could result in death or serious injury Indicates a hazard which if not avoided could result in minor or moderate...

Страница 3: ...struction Impeller Length Pumped ESE40M 4 10 115 1 11 0 6600 26 Cast Iron Thermoplastic 20 2 ESE40W 4 10 115 1 11 0 6600 26 Cast Iron Thermoplastic 20 2 ESE50M 1 2 115 1 12 0 7800 27 Cast Iron Thermop...

Страница 4: ...nd or severe damage to pump and will void the warranty a Using an extension cord b Cutting off the ground pin or using an adapter fitting c Working on pump or switch while plugged in d Removing motor...

Страница 5: ...emoval of the pump The remainder of the discharge line should be as short as possible with a minimum of turns to minimize friction head loss Do not restrict the discharge to sizes below 2 Sewage and e...

Страница 6: ...tart and stop several times by plugging in and unplugging cord Check for clogged vent hole in pump case Vertical pumping distance is too high Reduce distance or change the discharge fitting of the pum...

Страница 7: ...any alleged defect Manufacturer will subsequently take corrective action as promptly as reasonably possible No requests for service will be accepted if received more than 30 days after the warranty ex...

Отзывы: