32
4. Release the two tangs at each side of the module.
6. Slide the PCB out. Remove the jumper from JP4. You can hang it on one pin of JP4
when “off”.
7.
Slide the PCB into the enclosure until the two tangs “click”.
8.
The lambda module is now in EIB mode and can be on the EIB with a display.
To convert a module from EIB to Stand-alone Mode
The process is similar to the previously-described procedure. Note that in EIB mode, the module
will not show up in the device list of the configuration program.
1.
Use the Configuration Tool (software) to “Set to Stand-alone Mode”.
2.
Install the jumper on JP4 in the lambda module.
3.
In Stand-alone Mode, the module will continuously broadcast data via 500kbps CAN.
JP4
Jumper
Содержание NH3CAN