18
identified using Product Code, Revision Number and Serial Number, (these can be found on a
white label placed on the top of the plastic enclosure).
MULTIPLE MODULES ON BUS
SINGLE MODULE ON BUS
The module will reply with byte 0 = 0x44 on CAN id 0x7E4 if it enters LSS configuration mode
successfully.
The next message sent contains the new NID as an unsigned hexadecimal character.
CAN id
byte 0
byte 1
0x7E5
0x11
new NID
The module will reply with byte 0 = 0x11 and byte 1 = 0x00 on CAN id 0x7E4 indicating a
successful NID change.
The last message sent takes the module out of configuration mode.
CAN id
byte 0
byte 1
0x7E5
0x04
0x00
After the NID has been successfully changed, the module enters pre-operational mode and does
not broadcast data. The module can be returned to broadcast mode 1 of 3 ways:
i) Power-cycle the module by disconnecting and reconnecting the power.
ii) A second method is to send a command instructing the module to perform a hard reset
(similar to power-cycling the module but software controlled).
CAN id
byte 0
byte 1
0x00
0x81
NID
iii) A third method is to send a command instructing the module to reset the CAN
interface only.
CAN id
byte 0
byte 1
0x00
0x82
NID
Example: Change the NID for the following module with
multiple modules
on the CAN bus.
CAN id
byte 0
byte 1
byte 2
byte 3
byte 4
0x7E5
0x04
0x00
0x7E5
0x40
0xC6
0x01
0x00
0x00
0x7E5
0x41
Product Code
0x7E5
0x42
Revision Number
0x7E5
0x43
Serial Number
CAN id byte 0
byte 1
0x7E5
0x04
0x01