27
ResetTPDOs
0x1F
Set all TPDOs as delivered from factory. None
FastSensorStart
0x20
Use sensor start parameters in 1wire
memory
None
SlowSensorStart
0x21
Sensor start draws <1A max
None
FactoryReset
0xDF
Set all EE values to standard
configuration
None
ExpertModeEnable
0xE0
This command places the unit in expert
mode (password required)
None
HtrPidEnable
0xE1
Enable heater PID control
None
HtrPidDisable
0xE2
Disable heater PID control
None
RvsEnable
0xE3
Enable RVS measurement
None
RvsDisable
0xE4
Disable RVS measurement
None
UseCalibratedValues
0xE5
Use calibrated ADC/DAC values
None
UseUnCalibratedValues
0xE6
Use raw uncalibrated ADC/DAC values
None
UseProgrammedFilter
0xE7
Use programmed recursive average filter
constants (std)
None
UseCalibrationFilter
0xE8
Use slow recursive average filter
constants (cal)
None
Содержание NH3CAN