P0031-LI-02.01
29
No
Type & Description
0010 Confirmed
Alarm
This output type activates when two different zones cause
an intruder alarm.
0011 Alarm
Abort
This output type activates when the user disarms the system
after an alarm and within the “Abort Delay” period.
0012 Fire
Alarm
This output type activates when a fire alarm is generated.
0013 PA
Alarm
This output type activates when a panic alarm is generated.
0014 Duress
Alarm
This output type activates when a duress alarm is generated.
0015 24hr
Alarm
This output type activates when a 24hr alarm is generated.
0016 Medical
Alarm
This output type activates when a medical alarm is
generated.
0017 Tamper
Alarm
This output type activates when a tamper alarm is
generated.
0018 Ready
This output type activates when the system is ready for
arming, i.e. all zones are healthy.
0019 Trouble
This output type activates when a trouble alarm is
generated.
0020 Alert
This output type activates when an alert event is generated
and deactivates when the user has acknowledged the alert.
0021 Zone
Bypass
This output type activates when one or more zones are
bypassed.
0022
In Walk Test
This output type activates when the user walk test mode is
selected.
0023
Flash 1 Second
This output type continually pulses on and off at a rate of 1
second.
0024
User Test Active
This output type activates when the user test mode is
selected in the “Bell Test” menu.
0025 PSTN
Fault
This output type activates when a fault is detected on the
PSTN connected to the control panel.
0026
PSTN Off Hook
This output type activates when an off-hook condition is
detected on the PSTN connected to the control panel.
0027 PSTN
Ringing
This output type activates when ringing is detected on the
PSTN connected to the control panel.
0028 Battery
Fault
This output type activates when a fault is detected with the
control panel standby battery.
0029
Box Tamper Fault
This output type activates when the control panel box
tamper is open.
0030
Bell Tamper Fault
This output type activates when the control panel bell
tamper is open.
0031 Engineer
on
Site
This output type activates when the engineer is logged on.
0032 Detector
Reset
This output type is normally active and is used for powering
devices that require their power supply to be removed in
order to reset them. The output deactivates for 5 seconds at
the start of exit mode and when the system is reset.
No
Type & Description
0033 Detector
Latch
This output type is used to latch the alarm condition on
detection devices that have a latch input.
0034 System
Low
Volts
This output type activates when a low voltage fault is
detected with the control panel standby battery.
0035 In
Exit
This output type activates when the system is in exit mode.
0036 In
Entry
This output type activates when the system is in entry mode.
0037
In Second Entry
This output type activates when the system is in second
entry mode.
0038 In
Alarm
This output type activates when any alarm is generated.
0039 Auxiliary
Alarm
This output type activates when an auxiliary alarm is
generated.
0040 Warning
Alarm
This output type activates when a warning alarm is
generated.
0041 Keypads
Locked
This output type activates when a security key is active.
0042 Output
Fault
This output type activates when a fault is detected on one of
the monitored control panel outputs.
0043 Call
Engineer
This output type activates when the system requires an
engineer access code in order to reset the system.
0044 Device
Fault
This output type activates when a device fault is detected.
0045 Service
Required
This output type activates when the service timer expires.
0046 Cleaner
Bypassed
This output type activates when a “Cleaner Bypass” is
invoked.
0047 N/A
Not available on the EC-P8.
0048 N/A
Not available on the EC-P8.
0049 N/A
Not available on the EC-P8.
0050 Door
Access
This output type activates for 30 seconds when any valid
user code is entered.
0051 Alarm
Test
This output type activates when the user select the alarm
sounder test.
0052
Panel AC On
This output type activates when the mains supply is present.
Group 02: Control Timer
The EC-P8
has 5 control timers each timer can be assigned to an
output:
No
Type & Description
0201
Control Timer 1
This output type activates when Control Timer 1 is on and
deactivates when Control Timer 1 is off.
0202-
0205
Control Timer 2 - 5
As Control Timer 1.
Содержание EC-P8
Страница 1: ...EC P8 8 18 Zone Intruder Alarm System Installation Manual...
Страница 4: ...4 P0031 LI 02 01 1 System Overview System Configuration...
Страница 45: ...P0031 LI 02 01 45 Notes...
Страница 46: ...46 P0031 LI 02 01 Notes...
Страница 47: ...P0031 LI 02 01 47 Notes...
Страница 48: ...Technical Support Email support zetaalarmsystems com...