P0016-LI-03.01 

LCD LED 

Description 

"6-!G

RP ? A 

A panic alarm was generated at keypad ? by pressing keys 7 and 9. 

"6-! &/"G

RF ? A 

A fire alarm was generated at keypad ? by pressing keys 1 and 3. 

"6-!"!& )G

RD ? A 

A medical alarm was generated at keypad ? by pressing keys 4 and 6. 

21-21G 2)1

OPF ? 

The control panel has detected a fault on panel output ?. 

21-21G"01,/"

OPR ? 

The fault on panel output ? has restored. 

,*,!2)")/*

C?A 

The communication module has been disconnected/lost from com port ?. 

,*,!2)""01,/"

C?R 

The communication module has been connected/found from com port ?. 

,+"GG,2+1)/*

??CA 

Zone ?? has reached the “Count Logging” threshold. 

 

Содержание EC-P50

Страница 1: ...EC P50 10 50 Zone Intruder Alarm System Installation Manual...

Страница 2: ...ramming 19 Zone Type 19 Zone Wiring 20 Zone Attributes 20 Zone Areas 21 Zone Bypass Options 21 Zone Chime 21 Zone Soak Test 21 Zone Text 21 Zone Link 21 2 Area Options 22 Area Timers 22 Area Arming Mo...

Страница 3: ...8 System Users 41 User Access Code 41 User Type 41 User Locked By 41 User Name 41 User Link 41 User Areas 41 9 Utilities 42 Time and Date 42 User Menus 42 Away Arm A 42 Stay Arm S 42 Walk Test 11 42 T...

Страница 4: ...4 P0016 LI 03 01 1 System Overview System Configuration...

Страница 5: ...dedicated system status LEDs for AC Ready Armed Trouble Bypass Alert and Alarm are also provided Other features include f Internal sounder f Backlit keyboard EC LCD Remote Keypad The LCD keypad featu...

Страница 6: ...nting Mount the control panel on a flat plumb wall using at least three appropriate screws The rear casing has been designed with a central key hole slot so that mounting is possible without removing...

Страница 7: ...A L E N To Power Supply Module 4 Mains Supply Cable Entry The mains supply cable must be routed into the control panel housing via this cable entry 5 Communication Module An optional Eclipse Communica...

Страница 8: ...n auto resetting fuse PTC rated at 1 1 Amp 8 Speaker These terminals are used for driving 16 extension loudspeakers see page 12 9 Bell Tamper Return This terminal is connected to the tamper return con...

Страница 9: ...s 750mA This is the recommended charge rate for a 17Ah standby battery The system will fully recharge a flat battery within 24hours 18 Battery On Kick Start When powering the system from battery only...

Страница 10: ...gether and wired into the terminal at the control panel only The maximum recommended distance for devices when using standard 7 0 2 alarm cable is f 250m for each branch when using the star parallel c...

Страница 11: ...e EC P50 provides 10 zones for connecting detection devices such as movement sensors and magnetic door contacts Each zone is fully programmable to allow for maximum flexibility see page 19 for Zone Pr...

Страница 12: ...Com 1 Detector 2 Detectors Alarm Tamper E O L Alarm Tamper Alarm Tamper E O L 4K7 2K2 4K7 4K7 2K2 Triple EOL This wiring configuration should be used when connecting detection devices that support tri...

Страница 13: ...ct this terminal to the strobe input on the external sounder strobe unit Control Panel 12V TR 0V 1 2 External Sounder Tamper 0V 12V Suppy Bell ve Strobe ve Panel Outputs 1 5 The control panel has five...

Страница 14: ...hat some powered detectors e g PIRs and combined technology detectors take several minutes to warm up before they become operational f Test the internal sounder external sounder and strobe as describe...

Страница 15: ...Options 1 Area 1 Options 2 Area 2 Options 3 Area 3 Options 4 Area 4 Options 5 Area 5 Options 22 3 System Configuration 1 System Timers 2 System Counters 3 Hardware Options 4 Configuration 5 Control T...

Страница 16: ...ech Dialler Engineers Menu 7400 UDL Options Engineers Menu 8100 User Codes Engineers Menu 9001 Adjust Clock A S Section start location Section description A S Next up Previous down Select section Engi...

Страница 17: ...number The figures below show the programming procedure for both LED and LCD remote keypads Bit Toggle Selection LED Keypad En 1 3 0 1 Enter Engineers code Enter location No e g 1301 Press to display...

Страница 18: ...rrent value are displayed 0 Enter required value e g 35 String Edit Number Mode This type of data entry is used for entering a long string of numbers such as telephone and account numbers The figures...

Страница 19: ...activation of the zone will start the Entry 1 Delay timer for the relevant arm mode 02 Final Exit 2 Use this zone type for an alternative entry exit detector The zone can be activated during the exit...

Страница 20: ...ect wiring type in order for the correct response Locations 1201 to 1250 Zone 01 to 50 Zone Wiring Entry Mode Mode Selection List see page 16 0 Normally Closed Use this wiring type for normally closed...

Страница 21: ...e is not bypassed at the end of exit mode and the system will fail to arm if the zone remains active 6 Keyswitch Bypass On The zone is bypassed when a Bypass Key zone type is active and reinstated whe...

Страница 22: ...Entry Mode Bit Toggle Selection see page 17 0 Final Exit When the exit mode is started the selected area will only arm after the activation of a Final Exit 1 or Final Exit 2 zone type e g after the fr...

Страница 23: ...of options controls how the selected area responds when a keyswitch zone is used for arming Locations 2143 Area 1 Keyswitch Control 2243 Area 2 Keyswitch Control 2343 Area 3 Keyswitch Control 2443 Ar...

Страница 24: ...ce Required event is generated Default 0 weeks 10 Confirmation Period This timer controls the duration 0 255 minutes in which a confirmed alarm event can be generated When the system is armed and an i...

Страница 25: ...ed 4 Battery Presence On The standby battery is monitored for its presence Off The standby battery is not monitored 5 Mains AC On The mains supply is monitored for its presence Off The mains supply is...

Страница 26: ...e page 19 Area Labels This set of options allows you to assign a text label for each area e g Shop floor for area 1 The area label can be displayed when the user arms and disarms the system or it can...

Страница 27: ...covers programming of the remote keypads Keypad Options 1 This first set of options controls how the selected keypad onboard keys and tamper function Locations 4111 to 4114 Keypads 1 to 4 Options 2 En...

Страница 28: ...tones 8 Tamper Tones On The selected keypad generates tamper alarm tones Off The selected keypad will not generate tamper alarm tones Keypad Areas Keypads must be assigned to one or more areas to ens...

Страница 29: ...lection see page 17 1 Alarm Tones On The selected expander generates alarm tones Off The selected expander will not generate alarm tones 2 Trouble Tones On The selected expander generates trouble tone...

Страница 30: ...ows the output attributes to be assigned to the control panel high current outputs Locations 6121 to 6125 Panel Outputs 1 to 5 Output Attributes Entry Mode Bit Toggle Selection see page 17 1 Latching...

Страница 31: ...s in the disarmed state 0004 Armed This output type activates when the system is armed in any of the armed modes Away or Stay 0005 Part Armed This output type activates when the system is armed in any...

Страница 32: ...eset the system 0044 Device Fault This output type activates when a device fault is detected 0045 Service Required This output type activates when the service timer expires 0046 Cleaner Bypassed This...

Страница 33: ...Link Control 02 AND Location 3904 System Armed Link 102 Link Control 02 AND As the figure above shows the Link Control 02 will be active logic 1 only when ALL of the input links are closed active Lin...

Страница 34: ...ode 6202 Com Port 2 Mode Entry Mode Selection List see page 16 0 UDL USB Link This mode configures the selected communication port for UDL USB Link operation The USB Link should be connected to the co...

Страница 35: ...m 0193010 Belgium Belgacom 14974800 France France Telecom 0809101000 Switzerland Swisscom 0622100000 Netherlands KPN Telecom 0673644444 South Africa Telkom 1091969 Caller Line Identity must be enabled...

Страница 36: ...d for each ARC Locations 7031 to 7034 ARC 1 to 4 Protocol Options Entry Mode Bit Toggle Selection see page 17 1 Switch to Next ARC on failed Attempt On The on board communicator switches to the next A...

Страница 37: ...in area 2 are reported to ARC Off Events that occur in area 2 are not reported 3 Area 3 On Events that occur in area 3 are reported to ARC Off Events that occur in area 3 are not reported 4 Area 4 On...

Страница 38: ...On For location 7202 channel 2 is enabled for location 7242 channel 10 is enabled Off For location 7202 channel 2 is disabled for location 7242 channel 10 is disabled 3 Restore Channel 3 11 On For lo...

Страница 39: ...ledges the call but the dial sequence will continues with next number The speech messages are recorded using the Eclipse UDL software package or a touch tone telephone The touch tone method is covered...

Страница 40: ...er of remote UDL computer s modem must be configured using this option Location 7403 Entry Mode String Edit Number Mode see page 18 UDL Dial Sequence This set of options allows the dial sequence to be...

Страница 41: ...example if the user is assigned to all areas and keypad 1 is assigned to area 1 then the user can only arm and disarm area 1 from keypad 1 7 Arm Only The selected user is an Arm Only user and can only...

Страница 42: ...eir command numbers are scrolled on the bottom line of the LCD If the key is pressed the menu option that is currently being displayed is selected Away Arm A Selecting this option will cause the syste...

Страница 43: ...on off 24 Selecting this option will globally turn chime on or off Change Code 81 Selecting this option allows you to change your own access code After selecting this option enter the new access code...

Страница 44: ...d by zone GG 01 TR Tamper zone restore GG 2 1 FltA Fault alarm activated by zone GG 2 1 01 FltR Fault on zone has restored GG 0 MA Mask alarm activated by zone GG 0 01 MR Mask alarm on zone has restor...

Страница 45: ...as restored 25 20 AFAL The auxiliary 12V fuse has gone open circuit electronic fuse 25 20 01 AFAR The auxiliary 12V fuse has restored 11 6 20 BFAL The battery fuse has gone open circuit electronic fus...

Страница 46: ...A medical alarm was generated at keypad by pressing keys 4 and 6 21 21 G 2 1 OPF The control panel has detected a fault on panel output 21 21 G 01 OPR The fault on panel output has restored 2 C A The...

Страница 47: ...ected a fault with the telephone line PT The box tamper on the control panel has activated BT The bell tamper on the control panel has activated CE Call engineer to reset the system 3 2 CR The service...

Страница 48: ...LED Remote Keypad Electrical Voltage 9 16VDC Current 25mA quiescent 40mA when active Environmental Operating Temperature 25 C to 55 C 13 F to 131 F Storage Temp 25 C to 60 C 13 F to 140 F Max Humidity...

Страница 49: ...Packed Weight 100g Standards Safety Conforms to European Union EU Low Voltage Directive LVD 2006 95 EC EMC Conforms to European Union EU Electro Magnetic Compatibility EMC Directive 2004 108 EC Secur...

Страница 50: ...50 P0016 LI 03 01 Notes...

Страница 51: ...P0016 LI 03 01 51 Notes...

Страница 52: ...Technical Support Email support zetaalarmsystems com...

Отзывы: