P0016-LI-03.01
7
Control Panel Layout
1
3
4
6
2
5
1. Main Printed Circuit Board (PCB)
The main PCB that provides the terminals connection to remote
keypads and detection devices, see PCB Layout on next page for
full details.
2. Switched Mode Power Supply
The switch mode power supply module is housed under this
protected area and provides power to the main PCB via the three-
way harness.
3. Mains Connection
The AC Mains supply is connected to a 3 way Euro Type fused
terminal block, which is fitted with a 500mA fuse.
Fuse T500mA
L
E
N
To Power Supply
Module
4. Mains Supply Cable Entry
The mains supply cable must be routed into the control panel
housing via this cable entry.
5. Communication Module
An optional Eclipse Communication Module can be clipped into
the housing under the main PCB.
6. Standby Battery
The system housing will accept a 12V 7Ah battery to provide
continued operation in the event of an AC mains failure. Connect
the red battery lead to the positive terminal of the battery and
then connect the black battery lead to the negative terminal.
Control Panel
RD
Network
BA
T
12V 7Ah
Sealed Lead Acid Battery
The system will only become “live” when the AC supply is
connected or the “Battery On” pins are shorted, see
item 18 of PCB layout.