P0016-LI-03.01
23
7
Bell on Arm Fail
On: If the selected area fails to arm, the external sounder and
strobe is activated.
Off: The external sounder and strobe are not activated.
8
Pulse Strobe on Arm
On: When the selected area is armed successfully, the external
strobe is activated for 5 seconds.
Off: The external strobe is not activated.
Area Configuration Options 2
This second set of configuration options controls the operation of
each area.
Locations:
2142
- Area 1 Configuration Options 2.
2242
- Area 2 Configuration Options 2.
2342
- Area 3 Configuration Options 2.
2442
- Area 4 Configuration Options 2.
2542
- Area 5 Configuration Options 2.
Entry Mode:
Bit Toggle Selection (see page 17).
1
Only Exit when Ready
On: The exit mode can only be started if all zones are healthy
(System Ready) for the selected area.
Off: The exit mode can be started even if one or more zones are
active. The active zones will be indicated on the remote
keypads and a fault tone is generated.
2
Instant Bell on ATS Fault
On: The selected area bell delay is overridden and set to zero,
when the Alarm Transmission System (ATS/on-board
communicator) fault occurs.
Off: The selected area bell delay remains unchanged, when an
ATS fault occurs.
3
Alarms are Engineer Reset
On: Intruder alarms generated in the selected area require an
engineer to reset the system back to normal.
Off: Intruder alarms in the selected area can be reset by users.
4
Enable Bell Squawk
On: The bell output is pulsed once for a very short period when
the selected area is armed and twice when disarmed.
Off: The bell output operates as normal for the selected area.
5
Enable Walk Squawk
On: The bell output is pulsed once for a very short period when a
zone is activated during a walk test in the selected area.
Off: The bell output operates as normal for the selected area.
6
Enable Walk Voice
On: The zone and number (e.g., “Zone 10”) is announced
through the loudspeaker when a zone is activated during a
walk test in the selected area.
Off: The bell output operates as normal for the selected area.
7
Chime = Link 99
On: The chime feature is automatically turned on and off by Link
Control 99.
Off: The chime feature must be manually turned on or off by the
user.
Area Keyswitch Control
The set of options controls how the selected area responds when
a keyswitch zone is used for arming.
Locations:
2143
- Area 1 Keyswitch Control.
2243
- Area 2 Keyswitch Control.
2343
- Area 3 Keyswitch Control.
2443
- Area 4 Keyswitch Control.
2543
- Area 5 Keyswitch Control.
Entry Mode:
Bit Toggle Selection (see page 17).
1 Silent
Arm
On: The exit tone remains silent during exit mode, when a
keyswitch is used to arm the selected area.
Off: The exit tone is generated during exit mode, when a
keyswitch is used to arm the selected area.
2
Disabled when Armed
On: The keyswitch is disabled when selected area is armed (arm
only keyswitch).
Off: The keyswitch remains enabled when the selected area is
armed.
3 Instant
Arm
On: The selected area is armed instantly when a keyswitch is
used.
Off: The area exit mode is used to arm the selected area.
Area Timer Control
This set of options controls how the system Control Timers can be
used to automatically arm/disarm the selected areas at specific
times and on specific days of the week. Please refer to page 26
for details on Control Timer configuration.
Locations:
2151
- Area 1 Timer Control.
2251
- Area 2 Timer Control.
2351
- Area 3 Timer Control.
2451
- Area 4 Timer Control.
2551
- Area 5 Timer Control.
Entry Mode:
Bit Toggle Selection (see page 17).
1
Arm with Control Timer 1
On: The selected area is automatically armed by Control Timer 1.
Off: The selected area is not armed automatically.
2
Arm with Control Timer 2
On: The selected area is automatically armed by Control Timer 2.
Off: The selected area is not armed automatically.
3
Arm with Control Timer 3
On: The selected area is automatically armed by Control Timer 3.
Off: The selected area is not armed automatically.
4
Arm with Control Timer 4
On: The selected area is automatically armed by Control Timer 4.
Off: The selected area is not armed automatically.
5
Disarm with Control Timer 1
On: The selected area is automatically disarmed by Control
Timer 1.
Off: The selected area is not disarmed automatically.
6
Disarm with Control Timer 2
On: The selected area is automatically disarmed by Control
Timer 2.
Off: The selected area is not disarmed automatically.
7
Disarm with Control Timer 3
On: The selected area is automatically disarmed by Control
Timer 3.
Off: The selected area is not disarmed automatically.
8
Disarm with Control Timer 4
On: The selected area is automatically disarmed by Control
Timer 4.
Off: The selected area is not disarmed automatically.