10. Tighten the packing gland at the outer end of the atomizing
steam pipe. A final check on the location of the oil holes in
relation to the nose cone lip can be done as follows:
a. Connect the oil feed line to a water supply line and spray
water out of the nozzle at 5 PSIG.
b. If properly located, then the water streams emerging out of
the oil holes should be separate, distinct and uniform; the
water streams should also clear the inside lip of the nose
cone or just barely touch the lip’s edge.
11. Reinstall the oil gun into the burner and connect all hoses securely.
5-7
Eclipse Vortometric Burner v2.00, Installation Guide 248, 4/10/07