9. Operation
9.1. Power Switch
The power switch is located under dust cover.
Move the power switch to the ON position to energize the DC output of the charging station and the
peripheral wires. The TEST LED will not illuminate.
Move the power switch to the OFF position to de
‐
energize the DC output of the charging station and the
peripheral wires.
Move the power switch to the TEST position to energize the DC output of the charging station and the
peripheral wire(s). The TEST LED will illuminate.
9.2. LED Indicators
Four LED indicators are located on the input panel (rear side of charger).
WARNING
:
If an LED is not illuminated, AC power may still be present.
TEST LED
‐
Illuminates green when AC power is present and the power switch is in the TEST position.
SL (Station Loop) LED
‐
Blinks green when the station loop peripheral wire is correctly connected, blinks
red when incorrectly connected.
Z1 (Field Zone 1) LED
‐
Blinks green when Field Zone 1 peripheral wire is correctly connected, blinks red
when incorrectly connected.
1
‐
Power switch
3
‐
ON position
1A
‐
Power switch (side view)
4
‐
OFF position
2
‐
Dust cover
5
‐
TEST position
2
1
3
4
5
1A