38
T
ECHNICIAN
S
ETTINGS
M
ENU
M
OBILE
C
ONNECTION
Existing stations
If stations have already been defined a list of them is
presented.
Selecting a station enables you to view and edit the
properties of the station. These are the same as those
used in creating the station.
Create manual station
Allows you to manually create a new station.
This procedure is required to define a station that does
not use a positioning beacon.
Create new station
The charging station must be defined manually. Define
the following parameters.
Charge
This defines whether the charging station is used to
charge the robot or not.
Connected to parcels
This defines which of the defined parcels the station is
connected to. For a multi-field installation a list of
defined parcels will be presented and button next to
the required one must be checked ON.
NOTE
: This parameter must be defined for a multi-field
installation.
Station Inside Parcel's Wire
This specifies whether the station is located inside or
outside of the peripheral wire.
If the station is inside the wire, check the button ON.
Delete
Use to remove the manually created station from the
installation.
10.3.1 Station Properties
Station properties include details of a station. This
menu also allows you to specify
Access parameters
,
which determine how the robot will enter and leave
the station, and
Start Zones
, which are the points at
which the robot starts working after leaving the
station.
Charge
Defines whether the station is used to charge the robot
or not.
Software version
The current version of the software for the station.
Connected to parcels
This defines to which of the defined parcels the station
is connected. For a multi-field installation a list of
defined parcels will be presented and button next to
the required one must be checked ON.
NOTE
: This parameter must be defined for a multi-field
installation.
Station inside Parcel's wire
This specifies whether the station is located inside or
outside of the peripheral wire loop.
If the station is inside the loop, check the button ON.
Start Zones
This menu displays a list of the defined start zones and
enables you to create a new one. Start zones define
where the robot will start working after it has left the
station.
NOTE: A start zone defined here is only used for a
installation that contains a single wire and a positioning
beacon.
10.4 Mobile Connection
In the absence of a wireless network, the robot
contains a SIM card that enables you to use 4G tech-
nology in the field.
Select the
Mobile connection
in the list and press
.
Mobile Connection Options
Status
Displays the current mobile network status.
Network
Displays the name of the current network operator.
Network Carrier
Displays the name of the current network carrier.
APN
Displays the current id of the Access Point Name of the
SIM card.
Radio
3G/2G/UMTS/4G.
Signal Strength
Signal strength in dB.
DRAFT