analog inputs or through MODBUS protocol.
23. Power supply by 8-36VDC~24VDC
3. Menu Window Details
The flow meter user interface comprises about 100 independent windows. That are numbered by
M00,M01,M02……. M99,M+0,M+1 etc.
You do not need to remember all the menu windows. Just remember the most command used windows and
the proximate window numbers of some uncommonly used windows would be sufficient. You can always
use the going up and going down key to find the right window.
Note: 1 it is recommended to practice those menu windows on your flow meter while reading
this chapter for the sake of easier understanding.
2.To quickly switch to a menu window, simply press the ‘MENU’ key followed by the window
number (a two digit number). To move from one window to the next, use ‘UP’ or ‘Down’ keys.
00
display instant flow rate/net totalizer,adjust the units in M30-M32
01
display instant flow rate/instant flow velocity, adjust the units in M30-M32
02
display instant flow rate/positive totalizer, adjust the units in M30-M32
03
display instant flow rate/negative totalizer, adjust the units in M30-M32
04
display instant flow rate/date time
05
display heat flow rate/total heat quantity,adjust the units in M84 ,M88.
06
display temperature input T1,T2
07
display present battery voltage.(suitable to TDS16)
07
display analogue input AI3,AI4
08
display system error code
flow
rate/fl
ow
totalis
er
displa
y
09
display today net totalizer
10
input outside perimeter of pipe
*
11
input pipe outer diameter,data range:0-18000mm
*
12
input pipe wall thickness
*
13
input pipe inner diameter
*
14
choose the kinds of pipe materials
15
input sound velocity of pipe material
16
choose kinds of liner
17
input the sound velocity of liner
18
input the thickness of liner
19
input inner pipe wall absolute degree of roughness
*
20
choose kinds of fluids
21
input fluid velocity
22
input fluid viscosity
*
23
choose the types of transducers,including more than 20 types to use
*
24
choose transducer installation method
*
25
display transducer installation space
*26
parameter solidifying and setup
initial
setup
27
store and read installation parameters on installation point