F. Applications

Point of Use Models

 

Point of Use Models are designed to be connected to the COLD water line near the desired point of use 
needing hot water. Unit must be properly sized to provide sufficient hot water for the desired number 
of fixtures to be served. Contact your dealer or Eccotemp sales representative for assistance in sizing 
for your application.

Point of Use Models can also be connected to the HOT water line at the point of use to provide hot 
water sooner than is possible from the main hot water source located in a central location a longer dis-
tance from the fixture. As all Eccotemp models are temperature rather than flow controlled, the POU 
unit will modulate and add only the amount of energy necessary to maintain the hot water set point 
and return to standby once hot water arrives from the primary hot water source. This offers energy 
AND water savings over other alternatives such as recirculation.

Содержание EP-2.4

Страница 1: ...nline Eccotemp com products Store Locator Eccotemp com locator 866 356 1992 support eccotemp com 315 A Industrial Road Summerville SC 29483 ECCOTEMP Point of Use Tankless Water Heaters EP 2 4 EP 7 0 I...

Страница 2: ...referred service center does not already have Eccotemp service information Eccotemp will promptly provide the necessary information to the service center on request For information regarding service c...

Страница 3: ...e sure the bracket is level and in the proper orientation If mounting to a hollow wall care should be taken to locate a stud or to use appropriate hollow wall anchors After mounting the bracket slide...

Страница 4: ...er 5 Install ball valves on the inlet and outlet pipes to allow isolation of the heater for service Be sure both valves are open prior to activating the heater 6 Recommended operating pressure is 60 t...

Страница 5: ...shown and the ground to GND For 120V models connect the Neutral to L2 N on the terminal block PRE POWER CHECK 1 Verify that all connections are secure 2 Verify that an adequate ground has been proper...

Страница 6: ...ed application 2 If the design or structure of the Eccotemp heater is modified or altered in any way 3 If appliances or equipment not approved by Eccotemp are attached to the water heater 4 If the wat...

Страница 7: ...Point of Use Models can also be connected to the HOT water line at the point of use to provide hot water sooner than is possible from the main hot water source located in a central location a longer d...

Страница 8: ...uit board and verify the power connections are tight If stranded wire is used check that all strands are inside the lug Tests with Power ON Verify circuit breakers are turned on and verify power to th...

Страница 9: ......

Страница 10: ...nline Eccotemp com products Store Locator Eccotemp com locator 866 356 1992 support eccotemp com 315 A Industrial Road Summerville SC 29483 ECCOTEMP Point of Use Tankless Water Heaters EP 2 4 EP 7 0 I...

Отзывы: