background image

  

678/03.05.23/V2 

 
 
 

 

 

P a g e

| 16

 

of 28

 

 

Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom 

T

 | +44 (0) 1527 857 814           

E

 

[email protected]

           

W

 | www.eccostove.com 

 

For all patents 

 See Addendum 

Clean down through this into the stoves top; brush along the top flue chamber beneath the flue outlet 
and vacuum out that chamber by sliding a flexible vac hose to left and right. 
 

Seasonal Use.

 During a period when the stove will not be fired for example, during the summer 

period, leave the ash pit door open, 2mm, to minimise condensation build up within the stove.  
Clean the flue ways as described in the previous paragraphs (20. Cleaning and Maintenance) and 
clean out both the ashtray and fire box.  You may oil the outer paint surface with a light mist of 
releasing oil, similar to WD40 and leave for the next heating season.    
Check the rear back baffle boards and replace if cracked or broken.  
Check all seals are fixed firmly in place on the door; ash pit front and cleaning plugs.  
Remove and or clean above the steel gull wing baffle plate in the top of the firebox. 
Ensure the chimney flue and stove pipe are swept early summer time or after stoves shut down 
for the summer.  
Oil the door hinges and door catch mechanism all in readiness for the new heating season. 

a)

 

Adverse flue conditions (downdraught or pressurisation) will result in poor performance; door 
glass blackening and sooting in the flue ways.  Such conditions 

must

 be rectified by improving 

flue performance immediately.  Clean any tar/deposits off the door glass. 

b)

 

Repairs or replacements must be carried out by a competent engineer. 

 

Flueways are accessed by removing the cleaning plugs at a+ b + c + d and brushing vertically with the 
flue brush provided. 
 
Horizontal flue ways should be cleaned via the cleaning plugs at a + b + c + d and debris swept down in 
to the vertical flue ways. 
After cleaning vertically and horizontally the cleaning plugs at c and b should be removed and cleaned 
out with a vacuum cleaner or suction hose. 
 
Lastly remove the gull wing baffle at g and shake off 

 slide the whole assembly toward the rear of the 

stove and then left or right to drop down.  Re-instate in reverse order.  
 
Always check the flue is clear after a prolonged period of shutdown or non use. 
 
Vertical side flueways are cleaned through the top cleaning plugs along with the flue channels under the 
head of the stove through those self same plugs and soot / deposits should be vacuumed out through 
the face lower cleaning plugs to remove the debris cleaned down.  These plugs must always be re-fitted 
firmly in place before lighting or whilst running the Eco Stove.  The firebox door and ash pit door should 
remain closed at all times other than re-fuelling (fire box door) and ash pit door after following the 
lighting and re-fuelling procedures stated in these instructions. 
 
The Grate should be de-ashed by raking through the fire box door to ensure combustion air can flow 
through the grate bars (only carry out these works when the stove is not alight). 
 
The stove is now ready for re-use after all cleaning plugs have been re-fitted. 

Содержание 678EC

Страница 1: ...declare the whole or part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in...

Страница 2: ...www eccostove com For all patents See Addendum ADDENDUM Patents United Kingdom 2 213 945 E 2 467 433 United States 10 627 112 9 523 505 Canada 2 691 409 Germany 60 2010 064 710 2 Belgium 2 213 945 E S...

Страница 3: ...odifications to the appliance should be carried out without written consent of Landy Vent UK Ltd Only parts manufactured by Landy Vent UK Ltd shall be used within this appliance 1 INTRODUCTION 2 PURPO...

Страница 4: ...URE H FLUE OUTLET DIMENSION AND POSITION I HEAT ENERGY STORED J CO CONCENTRATION 24 DUCTED WARM AIR 25 GENERAL A SAFE OPERATION DISTANCES COMBUSTABLE AND NON COMBUSTABLE B MODIFICATIONS C PARTS D CHIM...

Страница 5: ...the UK The installer must be aware that all local regulations including those referring to National and European standards need to be complied with when installing the appliance Not every stove can b...

Страница 6: ...a top flue connection subject to specific order If the installation demands a 45 elbow can be taken directly from the top of the stove and back into the chimney Brest and hence the chimney flue The f...

Страница 7: ...ashed against them when loading stove Loading must be carried out with care 8 ASH GRATE The grate within your Eco Stove is made from cast iron being a highly durable material providing ash is not allo...

Страница 8: ...RNING Never spray aerosols in the vicinity of the stove when the stove is under fire 11 AIR CONTROLS Your Ecco Stove has three systems of air inlets for combustion 11A TERTIARY AIR MODEL 678EC The aer...

Страница 9: ...50 C or above It is important to note that the stoves performance is directly relative to the flue chimneys draft The stronger the draft the faster the stove will heat from cold and respond to the air...

Страница 10: ...ny wet items such as fire cements or adhesives for rope seals are allowed to dry before lighting the stove When the stove is first lit check all seals for soundness and check the flue is functioning c...

Страница 11: ...down no kindling needed 1 2kgs split logs maximum length 300mm maximum 60mm cross section load logs 2 crossways and 2 backwards in a splayed fashion with bark facing down with ashpit open maximum 1mm...

Страница 12: ...r door frame which holds the curve double leaf front of the baffle up in place Lift the weight of the baffle off the pins remove the pins and the baffle will hinge down and rest on the stoves grate ba...

Страница 13: ...draw would overfire the appliance To remove ash collected in the ash draw simply pull out the ash draw to its quarter extended position pull up safety catch lever on the side of the ash draw upon whic...

Страница 14: ...fuelling is carried out on a bright or lively fire if the stove body is below 150 C Open the door to the fire box slowly when re fuelling to minimise smoke spillage into the room as the door will crea...

Страница 15: ...r linings or coatings are suitable materials but ideally with a maximum flue area of 225 x 225 mm Pumice hot face linings with insulation or leka pelletts are suitable Under no circumstances should th...

Страница 16: ...by improving flue performance immediately Clean any tar deposits off the door glass b Repairs or replacements must be carried out by a competent engineer Flueways are accessed by removing the cleaning...

Страница 17: ...acer blocks one fixed front grate plug Two slide in vermiculite flueway dividers for left and right sides one cast iron grate Eleven further non structural parts are included being door section and fr...

Страница 18: ...No seals are fitted to this part Ensure it is located on its domed carbide locating pips by shuffling to bed into place Ba Fit the cast iron grate into the recess within the Silicon Carbide grate sec...

Страница 19: ...to the groove down left and right hand sides and across the grate section to enable the door frame to seal onto NOTE The tertiary air intake hole should be at the bottom and not the top of the back se...

Страница 20: ...at expansion joint used such as ceramic glass tape and then sealed with fire cement I It will be necessary to beat the trims into shape for an improved fit to reduce gaps as each piece moulds differen...

Страница 21: ...ue draught to be 04 inches water gauge f Flue gas mass flow 9 1 gs g Flue gas temperature Average 137 C at nominal output h Flue outlet 150mm top exit Dampers may be necessary if the flue draught is i...

Страница 22: ...amage leave the air controls fully open Recycling To dispose of the stove after the product life has expired please observe the following information o Dispose of the items correctly i e separate the...

Страница 23: ...supply and design The following parts are packed with the Ecco Stove 1 x Bottom section silicon carbide Ashcan 2 x alloy cleaning pugs 1 fixed alloy disc Model 850 only 1 x alloy t shaped joint seal l...

Страница 24: ...y be run day and night by repeated firings but will not burn for more then 2 4 hours on one filling or refuelling dependent on how well the fire draws and the density of fuel being burned and after wh...

Страница 25: ...ove com For all patents See Addendum Ecco Stove 678EC2 Description Value Nominal Heat Output 10 3 Net Efficiency 83 9 Particulate emissions 13 O2 mg m 21 OGC 13 O2 mg m 112 CO 13 O2 mg m 480 NOx 13 O2...

Страница 26: ...05 23 V2 P a g e 26 of 28 Ecco Stove Foster House 2 Redditch Road Studley B80 7AX United Kingdom T 44 0 1527 857 814 E sales eccostove com W www eccostove com For all patents See Addendum ECCO STOVE W...

Страница 27: ...pleted and returned to the Company within 21 days of installation see last page This warranty is void if the appliance is stripped and re assembled 3 Warranty Period Silicon Carbide parts are warrante...

Страница 28: ...the use of wood logs on your Ecco Stove Coals or processed petro chemical fuels void the warranty as their use may produce blockage in flueways Wood logs must be seasoned dried to 20 25 humidity to pr...

Страница 29: ...BY ADDRESS POSTCODE OR ZIPCODE TELEPHONE NUMBER INSTALLERS REGISTERED BODY AND NUMBER DATE THE ECCO STOVE WAS INSTALLED SELLING AGENT DEALER COMPANY NAME ADDRESS POSTCODE OR ZIPCODE TELEPHONE NUMBER E...

Страница 30: ...lake on the stoves outer body This typically occurs after re firing when the stove has periods without use during the colder weather or when building works such as fresh plaster have taken place in an...

Отзывы: