14. EXTRA CONTROLS
Excessive draft over .006 inches of water gauge may be moderated by installing a draft diverter or
damper into the flue pipe off the top of the stove and duly balanced. Speak to your retailer for advice or
fitting.
The Ecco stove is equipped to accept an outside primary air facility which requires an extra tube
extension and back box for installation.
Dampers left open.
Operation with the air control or appliance dampers open can cause excess smoke. The appliance must
not be operated with air controls, appliance dampers or door left open except as directed in the
instructions.
15. ASH REMOVAL
Ash removal must only be carried out when the stove is not alight as by removing the ash draw would
overfire the appliance.
To remove ash collected in the ash draw, simply pull out the ash draw to its quarter extended position;
pull up safety catch lever on the side of the ash draw upon which the ash draw may be fully extracted
for cleaning.
Always re-fit the ash draw after emptying fully following the lighting / firing procedure at 21 C in this
instruction manual.
16. FUELS
16a Wood
Wood as a fuel must be maximum 20% moisture content and split logs are nominally 300mm maximum
in length and up to 60mm in cross section or below for best combustion, (measured at any one point
over the width of the split log) see 25h) for explanation.
Harder, more dense logs or wood will generally burn more slowly. Timber should be loaded flat across
the width of the stoves fire box to ensure the end grain does not release volatiles towards the glass door
and hence blacken it quickly.
Under no circumstances must the Eco stove be used as an incinerator to burn household or industrial
waste of any description
–
only untreated 20% humidity wood must be used.
Liquid fuels must not be burned on this appliance.