580/03.05.23/V2
P a g e |
9
of 29
Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom
T
| +44 (0) 1527 857 814
E
W
| www.eccostove.com
For all patents
–
See Addendum
The combustion characteristics have not changed.
e)
RE LIGHTING (WITH OUTSIDE AIR)
Open the ash pit drawer 1-3mm or so to begin combustion and only close when the
stove has reached its optimum 160-18
0˚C top surface temperature. No other
adjustments can be made. Close the drawer at optimum temperature for automatic
operation to continue.
f)
CLOSING DOWN
Your Ecco Stove 580EC2 will continue in combustion at all times. No facility to shut it
down exists.
Close the flue damper if fitted (only after combustion is completed).
g)
FLUE DAMPER
To retain maximum heat within the appliance when heat retention is required and only
AFTER Primary combustion, close the flue damper, if fitted. ALWAYS open the damper
30 seconds before opening the stoves door or ash pit drawer.
Dampers left open
Operation with the air controls or appliance dampers open can cause excess smoke. The
appliance must not be operated with air controls, appliance dampers or door left open
except as directed in the instructions.
12.
FIRING THE STOVE
1.
Commissioning
Ensure all parts are fitted in accordance with these installation instructions.
Ensure that any wet items such as fire cements or adhesives for rope seals are allowed
to dry before lighting the stove.
When the stove is first lit, check all seals for soundness and check the flue is functioning
correctly and all products of combustion are venting safely to atmosphere via the
chimneys terminal.
Ensure the homeowner is given the operating instructions and a brief run through using
the instructions to demonstrate operation is made to familiarise the new user with the
procedures as set out in the operating instructions.
Clearly state fuels suitable for use on this stove (wood logs).
IMPORTANT advise the new user that should smoke or fumes be emitted from the stove
close the ash pit control on the stove; windows and doors should be opened
immediately to ventilate the room; and the room evacuated until specialist help and
advice (sweep or fire brigade) has been sought.
DO NOT OVER FIRE THE STOVE FOR ITS FIRST FIRING OR AFTER LONG PERIODS BETWEEN
BURN CYCLES.
Run for 2 hours with kindling and 50mm or less diameter wood for an initial gentle fire.