CC1310 Wireless Module
E70 Series User Manual
Copyright ©2012–2017, Chengdu Ebyte Electronic Technology Co., Ltd.
18
/
34
5.5 Reset
No.
Description
1
When the module is powered, AUX outputs low level immediately, conducts hardware self-check and sets the operating mode
on the basis of the user parameters. During the process, the AUX keeps low level. After the process completed, the AUX outputs
high level and starts to work as per the operating mode combined by M2, M1 and M0. Therefore, the user needs to wait the AUX
rising edge as the starting point of module’s normal work.
5.6 AUX Description
5.6.1 Indication of UART Output
To wake up external MCU:
5.6.2 Indication of Wireless Transmitting
Sub-package mode: the length of the buffer is determined by the length of sub-packages. If the packet is set as
1024 bytes, the buffer is 1024 bytes too. When Aux=1, users can transmit data continuously within 1024 bytes.
Continuous mode: When Aux=1, the length of packet is unlimited.
WOR mode: When Aux=1, users can send continuous data packet within 84 bytes.
When AUX = 1, it means that all the UART data of the module have been transmitted already.