CC1310 Wireless Module
E70 Series User Manual
Copyright ©2012–2017, Chengdu Ebyte Electronic Technology Co., Ltd.
15
/
34
27
AUX
Output
It is used to indicate the operation status of module, for user to wake up the external MCU,
the module outputs low level during self-checking and initialization at power on,
it can be
configured as open-drain output or pull-up output,
please refer to parameter setting par.
An external 1k protective resistor shall be connected in series while using
(
can be floated)
28
VCC
-
Power positive reference,
Power supply 2.6V ~ 5.5V DC
29
VCC
-
Power positive reference,
Power supply 2.6V ~ 5.5V DC
30
GND
Ground
Ground electrode
31
GND
Ground
Ground electrode
32
NC
Reserved pin
Reserved, to be floated
33
NC
Reserved pin
Reserved, to be floated
34
NC
Reserved pin
Reserved, to be floated
35
NC
Reserved pin
Reserved, to be floated
36
NC
Reserved pin
Reserved, to be floated
37
NC
Reserved pin
Reserved, to be floated
38
NC
Reserved pin
Reserved, to be floated
39
NC
Reserved pin
Reserved, to be floated
40
NC
Reserved pin
Reserved, to be floated
41
NC
Reserved pin
Reserved, to be floated
42
NC
Reserved pin
Reserved, to be floated
43
NC
Reserved pin
Reserved, to be floated
44
LNA_EN
Input
Internal LNA pin, valid in high level, connect to pin 11
45
PA_EN
Input
Internal PA pin, valid in high level, connect to pin 12
46
GND
Ground
Ground electrode
47
GND
Ground
Ground electrode
48
ANT
-
Antenna (50Ω characteristic impedance)
All E70 series are compatible with their pins.
Real values of MCU controlled PA and LNA are as follows:
No.
PA_EN
LNA_EN
Notes
1
1
0
In transmitting
2
0
1
In receiving
3
0
0
In sleeping mode