Chengdu Ebyte Electronic Technology Co.,Ltd.
E106-xxxTxxS User Manual
Copyright ©2012–2023
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
20
0
0
1
1
1
21K
0
1
0
0
0
26K
0
1
0
0
1
42K
0
1
0
1
0
51K
0
1
0
1
1
82K
0
1
1
0
0
76K
0
1
1
0
1
125K
0
1
1
1
0
160K
0
1
1
1
1
410K
1
0
0
0
0
470K
1
X
X
X
X
470K
04H
Read /
write
REG1
7
6
Serial check bit
* Module serial port check type
0
0
8N1 (by default)
0
1
8O1
1
0
8E1
1
1
8N1 (equivalent to 00)
5
Channel RSSI enables
* Only for general transmission
mode;
* When enabled, the instruction
"C0 C1 C2 C3" can be sent in
general transmission mode to
read register: register [0x00]:
current ambient noise RSSI [0];
register [0x 01]: RSSI [1] when
last received data;
* Conversion formula: dBm =
RSSI / 2-154;
* Instruction format resolution:
send: C0 C1 C2 C3 + starting
a read length; Return:
C1 + a read
read valid value; [Example 1]:
Send the C0 C1 C2 C3 00 01,
Return to C1 00 01 RSSI [0];
[Example 2]: Send the C0 C1
C2 C3 00 02, Return to the C1
00 02 RSSI [0] RSSI [1];
[Special Note] Address can
only start at 0x00, If required to
read the RSSI [1], Can only
refer to [Example 2] for
execution; If the module never
receives the data, The RSSI [1]
default value is 0x00.
0
Close (default)
1
open
4
3
continue to have
2
Type of policy in the continuous
transmission mode
* After the opening speed is
preferred, the data output delay
of the receiving end will be
reduced by about 60%, but it
will affect the receiving
distance. For example, in the
115200 rate continuous
0
Distance Priority (Default)
1
Speed first