5.3 Broadcast address
Example: Set module A address to 0xFFFF and channel to 0x04.
When module A is used as transmission (the same mode, transparent transmission mode), all the receiving modules
under the 0x04 channel can receive data to achieve the purpose of broadcasting.
5.4 Monitor address
Example: Set module A address to 0xFFFF and channel to 0x04.
When module A is received as, all the data under the 0x04 channel to achieve the purpose of monitoring.
5.5 Module reset
After the module is powered on, the AUX will immediately output the low level, conduct the hardware self-test, and
set the working mode according to the user parameters;
In this process, AUX keeps a low level, after which AUX outputs a high level, and starts to work normally
according to the combination of M1 and M0;
Therefore, the user needs to wait for the AUX to rise along, as the starting point for the normal operation of the
module.
5.6 AUX explanation
AUX is used for wireless sending and receiving buffer indication and self-test indication.
It indicates whether the module has data that has not been transmitted wirelessly, or whether the wireless data has
not been transmitted entirely through the serial port, or whether the module is in the process of initializing the
self-test.
5.6.1 Serial data output indication
For awakening the external MCU in dormancy;
AUX pin timing diagram when sending data from the module serial port