Ebyte Electronic Technology Co., Ltd E104-BT01 Usermanual
Copyright ©2012–2019
,
Ebyte Electronic Technology Co., Ltd
17
Disconnect: Disconnection
Note: Valid immediately
5.2.22 AT+DATDLY Query and Set Data Output Delay command
Command
Response
Parameter
Query: AT+DATDLY?
+OK=[para]
Para:0
、
1 ASCII
0: Off
1: On
S et: AT+DATDLY=[para]
+OK: S ucceed
+ERR=[NUM]: Error
Note: Valid immediately, power off preservation
5.2.23 AT+MAC Query MAC command
Command
Response
Parameter
Query: AT+MAC?
+OK=[para]
Para: 6 bytes M AC address HEX
E.g.: F0E1D2C3B4A5
Note: Valid immediately, power off preservation
5.2.24 AT+PEERMAC Query Connected device MAC command
Command
Response
Parameter
Query: AT+PEERMAC?
+OK=[para]
Para: 6 bytes M AC address HEX
E.g.: F0E1D2C3B4A5
Note: Valid immediately
5.2.25 AT+BOND Bonding MAC Address on/off command
Command
Response
Parameter
Query: AT+BOND?
+OK=[para]
Para: 0,1 ASCII
0: Off
1: On
S et: AT+BOND=[para]
+OK: S ucceed
+ERR=[NUM]: Error
Note: Valid immediately, power off preservation
5.2.26 AT+BONDMAC Query and Set Bonging MAC address command
Command
Response
Parameter
Query: AT+BONDMAC?
+OK=[para]
Para: 6 bytes M AC address HEX
E.g.: F0E1D2C3B4A5
S et: AT+BONDMAC=[para]
+OK: S ucceed
+ERR=[NUM]: Error
Note: Valid immediately, power off preservation