Ebyte Electronic Technology Co., Ltd E104-BT01 Usermanual
Copyright ©2012–2019
,
Ebyte Electronic Technology Co., Ltd
18
5.2.27 AT+SCAN Query and Set Broadcast scanning command
Command
Response
Parameter
Query: AT+S CAN?
+OK=[para]
Para: 0,1 ASCII
0: Off
1: ON
S et: AT+S CAN=[para]
+OK: S ucceed
+ERR=[NUM]: Error
Note: Valid immediately, power off preservation
5.2.28 AT+VER Query Firmware version command
Command
Response
Parameter
Query: AT+VER?
+OK=[para]
Para: version number 4 bytes ASCII
Note: Valid immediately
5.2.29 AT+AUTH Query and Set Air configuration authentication password command
Command
Response
Parameter
Query: AT+AUTH?
+OK: S ucceed
+ERR=[NUM]: Error
Para: 6 bytes password
ASCII/HEX
S et: AT+AUTH =[para]
+OK: S ucceed
+ERR=[NUM]: Error
Note:
1. Valid when next connection, power off preservation
2. Password cannot be modified before authentication succeeding
3. This command is only used in the air configuration
5.2.30 AT+PWR Query and Set TX power command
Command
Response
Parameter
Query: AT+PWR?
+OK=[para]
Para: 0~2 ASCII
0:-23dBm
1:-17dBm
2: 0dBm
S et: AT+PWR =[para]
+OK: S ucceed
+ERR=[NUM]: Error
Note: Valid immediately, power off preservation
5.2.31 AT+ONSLEEP Query and Set Power-on sleep command
Command
Response
Parameter
Query: AT+ONS LEEP?
+OK=[para]
Para: 0
、
1 ASCII
0: Off
S et: AT+ONS LEEP=[para]
+OK: S ucceed
Содержание CC2541