5.2.7 AT+ADVEN Query and set the broadcast on/off command
Command
Response
Parameter
Query: AT+ADVEN?
+OK=[para]
Para:0
、
1
、
2 ASCII
0: B
roadcast off
1: Normal broadcast
2: iBeacon broadcast
S et: AT+ADVEN=[para]
+OK: S ucceed
+ERR=[NUM]: Error
Note: Valid after disconnection, power off preservation
5.2.8 AT+ADVDAT Query and Set Broadcast data command
Command
Response
Parameter
Query: AT+ADVDAT?
+OK=[para]
Para: No more than26 bytes HEX
S et: AT+ADVDAT=[para]
+OK: S ucceed
+ERR=[NUM]: Error
Note: Valid when next broadcast, power off preservation
5.2.9 AT+ADVDAT1 Query and Set Broadcast data command (not saved)
Command
Response
Parameter
Query: AT+ADVDAT1?
+OK=[para]
Para: No more than26 bytes HEX
S et: AT+ADVDAT1=[para]
+OK: S ucceed
+ERR=[NUM]: Error
Note: Valid when next broadcast, power off not preservation
5.2.10 AT+ADVINTV Query and Set Broadcast interval command
Command
Response
Parameter
Query: AT+ADVINTV?
+OK=[para]
Para:32~16000 ASCII
E.g.: para=1600
1600*0.625ms=1s
S et: AT+ADVINTV=[para]
+OK: S ucceed
+ERR=[NUM]: Error
Note: Valid when next broadcast, p ower off preservation
5.2.11 AT+IBCNUUID Query and Set iBeacon UUID command
Command
Response
Parameter
Query: AT+IBCNUUID?
+OK=[para]
Para: 16 bytes HEX
S et: AT+IBCNUUID=[para]
+OK: S ucceed
+ERR=[NUM]: Error
Note: Valid immediately, power off preservation