7.
DEVICE PROGRAMMING
Programming of device is possible with “GPRS transmitters configurator”
configuration program described in chapter 5. To program the device establish
connection with a device.
Depending on connection mode there are two ways for programming.
7.1.
LOCAL PROGRAMING
To program a device locally follow the procedure:
a)
Connect PROG joint (on printed circuit) with COM computer port by way of
service wire, defined in option -> RS-232.
b)
Connect power supply to terminals
V+
and
GND
. After connection and detection
of programming wire a module shall signal this with LED diodes: a green one
shall flash and red one shall flicker.
c)
Launch software and define device options.
d)
Save settings into memory of device. Saving course is displayed in special
window.
e)
After saving disconnect power supply and disassembly service wire.
f)
Connect module wiring pursuant to guidelines. Turn power supply on.
g)
The device is ready to transmit data.
7.2.
REMOTE PROGRAMMING
The device can be programmed remotely if the user is working using an OSM.Server
monitoring system receiver and has correctly defined the remote connection based on
OSM.Server parameters.Since OSM.Server sends (and receives) information only from
devices that it has stored in its database, the first thing to do during remote programming
is to properly register the device. This procedure is described in the OSM.Server
Operating Manual.
7.2.1.
The first programming of device
As the device has no pre-defined Wi-Fi or OSM.Server access parameters, they must
be specified first.
Regardless on how this entry is made, the device must first be registered in the
OSM.Server database.
Follow the procedure: