WX2NB Manual v.1.0
Page 21 / 40
6.3.
INPUTS/OUTPUTS
Transmitter has got 4 signal inputs and additional input for sabotage signal switch-
key connection. Module is equipped with one output. In/Out option enable
programmable configuration so that transmitter operates pursuant to requirements
of the user.
All inputs of the device are 24 hour alarm inputs.
6.3.1.
Inputs configuration
For every input the following settings shall be determined respectively.
6.3.1.1.
Input mode
This parameter allows us to determine the steady state of the input. Change of this
state results in sending information on alarm. Allowable NC and NO input. NC input
shall be shorted to ground. Actuation follows after decay. NO input remains open. At
this moment of shortening to ground activation follows. EOL and DEOL are options
where you use 1 or 2 resistors to distinguish alarm from sabotage