WX2NB Manual v.1.0
Page 1 / 40
TRANSMITTER
WX2NB
Installation and
programming manual
Version of the manual:
v1.0
Date of issue:
2019.03.18
Firmware version:
2.5.2
GPRS transmitter configurator version:
1.4.91.4
Страница 1: ...2NB Manual v 1 0 Page 1 40 TRANSMITTER WX2NB Installation and programming manual Version of the manual v1 0 Date of issue 2019 03 18 Firmware version 2 5 2 GPRS transmitter configurator version 1 4 91...
Страница 2: ...ll not be deemed to be providing any warranties either express or implicit including but not limited to any implied warranties of merchantability or fitness for a particular purpose unless it is requi...
Страница 3: ...e monitor 16 5 3 13 Help About program 16 6 PROGRAMMABLE PARAMETERS 17 6 1 ACCESS 17 6 1 1 Device mode 18 6 1 2 Wi Fi settings 18 6 1 3 Network parameters 18 6 1 4 Data Transmission 18 6 2 TRANSMISSIO...
Страница 4: ...WX2NB Manual v 1 0 Page 4 40 9 1 LOGGING TO Wi Fi NETWORK 38 9 2 Wi Fi RANGE 38 9 3 DATA TRANSMISSION 38 9 4 PROGRAMMING 38 9 5 FIRMWARE UPDATING 39 9 6 SYSTEM ERROR 39 10 REVISION HISTORY 40...
Страница 5: ...data transmission from security systems installed in detached houses and in small business facilities It also have input for connection of an alarm control panel s phone communicator This provides for...
Страница 6: ...ng humidity 5 93 In dependence from user s decision transmitter can be delivered in different versions Therefore also the parameters as type of the power supply voltage current consumption as well as...
Страница 7: ...witch power off to perform any connection 3 1 WX2NB TRANSMITTER Figure 1 WX2NB Transmitter with LX ZAS a Connections of wires shall be made with due care to prevent any faults or dead shorts Places of...
Страница 8: ...amination a battery may be connected to AKU terminals of LX ZAS power supply and then power may be switched on for transformer and programming procedure of transmitter may begin see Chapter 6 Manufact...
Страница 9: ...cting battery protection against excessive unloading battery The battery protects before damage in case of long lasting fading the AC In case of lack the AC and unloading below voltage 9 5 V the batte...
Страница 10: ...return to their basic status To configure the transmitter to work with an emergency exchange telephone communicator the telephone number that the communicator reacts to must be entered in the transmit...
Страница 11: ...r computer system where configuration software is to be installed are the following Hardware Processor 1GHz or faster 1 GB RAM 4GB HDD Software Operating system Windows 7 or newer NET Framework 4 5 so...
Страница 12: ...sk under any name and it may be loaded later on This function save on disc any information from configuration wizard window After activation of function a dialog window appears with request to provide...
Страница 13: ...askbar and opening RS232 tab Define Name of connection e g Local Choose serial port e g COM1 Click on Add button to confirm settings Connections shall be saved and inserted in table From this time on...
Страница 14: ...tely to the device and enable reading and saving parameters to WX memory 5 3 6 File Automatic device settings backup All configuration settings including reread from devices and saved on devices are t...
Страница 15: ...de of transmitter 5 3 9 Operations Send This function is analogical to the above one at the same time it enables data saving into EEPROM module There is also possibility to set correct time into WX de...
Страница 16: ...back to default settings 5 3 11 Operations System events history Events history provides information about last events stored in WX device memory 5 3 12 Operations Device monitor Device Monitor provi...
Страница 17: ...unauthorized access It is used both when programming the device and when operating it remotely in Wi Fi mode By default it is set to 1111 It should be changed when the device is first activated progr...
Страница 18: ...s This section defines the IP address settings By default it is set to DHCP Dynamic Host Configuration Protocol but it can also be configured to static when this option is set the fields below turn ac...
Страница 19: ...ies the number of seconds before this signal is sent again 6 1 4 6 Always try to connect to primary server first Checking this field means that the device will attempt to connect to the primary server...
Страница 20: ...c time passes Further actions depend on how the Connection Order parameter is configured see section 6 1 4 6 If this option is active the device will attempt to connect to the primary server If this o...
Страница 21: ...hour alarm inputs 6 3 1 Inputs configuration For every input the following settings shall be determined respectively 6 3 1 1 Input mode This parameter allows us to determine the steady state of the i...
Страница 22: ...ption you can lock any input of module and as a result condition changes on this input will be ignored and will not be reported to monitoring station Lock may be persistent or temporary In case of tem...
Страница 23: ...Tb Tb Tb Tb Tb Input activation and deactivation Input activation and deactivation no reaction Temporary input lock Events send to server Event input active Event input not active Locally there can be...
Страница 24: ...is monitored only when partition to which input belongs is armed Input can be assigned up to one partition Arming inputs can not be assigned to any partition If input is not assigned to any partition...
Страница 25: ...available o Bistable connection follows for indefinite time up to the moment of disconnection of power for module or remote command which switches output off o Monostable connection follows for time d...
Страница 26: ...action to go over basic output configuration function described in Output configuration In the Advanced outputs control you may define separately the behaviour of the output depending on events takin...
Страница 27: ...urn on output temporarily output will be turned on for an amount of time specified by parameter o Turn off output output will be turned off Press the Reset button to assign the action Do Nothing for e...
Страница 28: ...from action to rest normalization To transmit any signal you should only click it proper square on your right Click on Clear button to remove all marked signals Click on Invert button to change marki...
Страница 29: ...the supply voltage falls below the defined threshold in this field POWER loss event is generated The minimum value possible to set is 8V maximum 13V Information about the end of POWER failure is sent...
Страница 30: ...wait for the specified time once it detects this fact then perform the specified tasks 6 6 PHONE LINE The device is equipped with simulated PSTN phone line which may collect information from an contr...
Страница 31: ...control panels require that during a receiver picking up a tone of dialling was actuated To enable cooperation with a transmitter it is possible to make a transmitter to generate such tone 6 6 1 4 De...
Страница 32: ...0 sec European Standard determines this value at 0 5 to 12 5 sec 6 6 2 3 Protocol Select protocol of data transmission used by an alarm control panel and that is acceptable for monitoring station Cont...
Страница 33: ...l Note Procedure of assigning firmware to a device is analogous to programming a device For procedure refer to chapter 6 Programming of the device e Click Start button to start software exchange f Loa...
Страница 34: ...ters are also shown in LOG window in text style All data can be saved to file 6 9 EVENTS HISTORY Events history provides information about last events stored in WX device memory WX transmitter is able...
Страница 35: ...e Saving course is displayed in special window e After saving disconnect power supply and disassembly service wire f Connect module wiring pursuant to guidelines Turn power supply on g The device is r...
Страница 36: ...memory of device Saving course is displayed on special window g After saving completion close configuration wizard h The device is ready to transmit data 7 2 2 Reprogramming of device As the device ha...
Страница 37: ...uts outNr specifies output number 0 for OUT1 state specifies requested output state 0 switched off 1 switched on Below are allowed combinations OUT 0 0 switches off TMP output OUT 0 1 switches on TMP...
Страница 38: ...RANGE Flickering of a green diode indicates Wi Fi signal 1 8 flickers Device operation mode is signalled with a green diode on during 2 seconds once the range was detected Description LED Diodes Gree...
Страница 39: ...ws during updating there is bootloader in device and another programming of device is possible Description LED Diodes Green Red No program in device 1 sec Software updating Received firmware decoding...
Страница 40: ...WX2NB Manual v 1 0 Page 40 40 10 REVISION HISTORY Date Version Description 18 03 2019 v1 0 First version...