
LX2NB Manual v.1.3
Page 31 / 57
o
Bistable – connection follows for indefinite time – up to the moment of
disconnection of power for module or remote command which switches
output off,
o
Monostable – connection follows for time defined by user – every 100ms.
7.3.3.2.
Conditions
Defines conditions for activating output. User can set following conditions:
o
No connection to server (immediately after detection);
o
No GSM signal (immediately after detection);
o
Detection of incoming call from defined telephone number;
After selecting this option can be generated CLIP event, if appropriate
position in the “Monitoring” group is set (see item 7.4.5.). You can enter full
phone number or only a part of number. The device will detect all numbers
with specified sequence. E.g. if entered number is
1234
, the output will
activate after incoming call from number
1234
56789 or 600
1234
56.
Note: The phone number must me entered without country code (e.g.
without prefix 0048 and +48).
o
Dependent on state transitions from non-active to active of one of the inputs.
Output can be also activated by internal watchdog, which can be configured in “Link
control” group.
7.3.3.3.
Additional conditions
If option “Dependent on state transitions from non-active to active of one of the
inputs” is chosen, we might configure additional conditions for output activations:
o
Never:
input disturbance does not cause operation of sabotage output,
o
No network:
input disturbance causes actuation of sabotage output if sending
of information to server is impossible.
o
Always:
every input disturbance causes actuation of sabotage output.
o
Available network:
input disturbance causes actuation of sabotage output if
sending of information to server is possible.
Note:
Output may be controlled by SMS commands.
7.3.4.
Advanced outputs control
The user is able to determine an alternative course of action to go over basic output
configuration function described in 7.3.3 Output configuration
.
In the “Advanced
outputs control” you may define separately the behaviour of the output, depending
on events taking place. “Advanced outputs control” differs from the existing basic
“Outputs configuration” by:
o
it is possible not only to turn on but also to turn off the output
o
output can be activated temporarily for specified amount of time
o
there is a complete list of events for which you can define the behaviour of
the output
Содержание LX2NB
Страница 49: ...LX2NB Manual v 1 3 Page 49 57...