N

UMBER

 

D

ESCRIPTION

 

P

ART 

N

UMBER

 

Q

UANTITY

 

1 Defrost 

Timer 

1600550  1 

2 Control 

Knob 

2019708  1 

3 Capillary 

Tube 

3014251  48” 

4 Solenoid 

Valve 

3020814  1 

5 Filter 

Dryer 

3020901  1 

6 Compressor 

3022163  1 

7 Solenoid 

Coil 

3030421  1 

8 Capacitor 

3030908  1 

9 Humidistat 

3035145  1 

10 Mains 

Lead 

3035148  1 

11 Fan 

Motor 

3035788  1 

12 Relay 

3036157  1 

13 Axial 

Fan 

3040129  1 

14 

Fan Inlet Ring 

3040326 

15 Rubber 

Foot 

3101436  1 

16 

Drain Tubing 

3014338 

9 Feet 

17 

Drain Tube Jubilee Clip 

3086101 

18 Condenser 

Coil 

2026014  1 

19 Evaporator 

Coil 

2026013  1 

 

Содержание CS60

Страница 1: ...CS60 OWNERS MANUAL Drawing No TPC302 Issue 1 Date 12 07 04 EBAC MODEL CS60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL...

Страница 2: ...quipped with a permanent drain The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling phase plus the additional heat generated...

Страница 3: ...TIONS MODEL CS60 HEIGHT 13 25 336 55mm WIDTH 13 75 349 25mm DEPTH 20 25 514 35mm WEIGHT 62 83lbs 28 5 kg AIRFLOW 360 CFM EXTRACTION 56 Pints Per Day At 80 F 60 RH POWER SUPPLY 115V 60Hz 1 ph FINISH Po...

Страница 4: ...eave the machine running for 15 minutes E Observe the evaporator coils through the rear upper grill to confirm frost operation i If the air temperature is below 80 F an even coating of frost should co...

Страница 5: ...ore does not need oiling 3 To check the refrigerant charge run the unit for 15 minutes and briefly remove the top cover The evaporator coil should be evenly frost coated across its surface At temperat...

Страница 6: ...of the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak cau...

Страница 7: ...s of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve 1 Conta...