INTRODUCTION 

 
 
 

Designed for a wide range of applications, the CS60 dehumidifier is a rugged, industrial unit 
which utilizes an energy-efficient compressor and a compact portable design to provide easy 
efficient drying. 
 
 
The CS60 has a number of special features: 
 
 

 

Compact Size 

 

High efficiency rotary compressor 

 

Ebac’s 

“Hot Gas”

 defrost system 

 

Exterior epoxy powder-coated finish 

 

Provision for permanent drainage 

 

All galvanized interior 

 

Extra long power cord 

 

Humidistat 

 
 
 
The fan draws the moist air through the cold evaporator coil, which cools the air below its dew 
point.  Moisture forms on the evaporator coil and is collected in the condensate tray, which is 
equipped with a permanent drain.  The cooled air then passes through the hot condenser coil 
where it is reheated using the same energy removed during the cooling phase, plus the additional 
heat generated by the compressor.  The air is, therefore, discharged from the dehumidifier at a 
slightly higher temperature with a lower absolute humidity than that which entered.  Continuous 
circulation of air through the dehumidifier gradually reduces the relative humidity within the 
area. 
 
 
The CS60 dehumidifier is a rugged, reliable drying unit designed to operate effectively over a 
broad range of temperature and humidity conditions.  An active hot gas defrost system, 
controlled by an electronic timer, guarantees positive de-icing, thereby optimizing operation at 
low temperatures.  
 
 
The unit incorporates a welded and galvanized steel chassis and is finished in an epoxy coating 
for resilience to damage caused by rough handling. 

 

 
 

Содержание CS60

Страница 1: ...CS60 OWNERS MANUAL Drawing No TPC302 Issue 1 Date 12 07 04 EBAC MODEL CS60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL...

Страница 2: ...quipped with a permanent drain The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling phase plus the additional heat generated...

Страница 3: ...TIONS MODEL CS60 HEIGHT 13 25 336 55mm WIDTH 13 75 349 25mm DEPTH 20 25 514 35mm WEIGHT 62 83lbs 28 5 kg AIRFLOW 360 CFM EXTRACTION 56 Pints Per Day At 80 F 60 RH POWER SUPPLY 115V 60Hz 1 ph FINISH Po...

Страница 4: ...eave the machine running for 15 minutes E Observe the evaporator coils through the rear upper grill to confirm frost operation i If the air temperature is below 80 F an even coating of frost should co...

Страница 5: ...ore does not need oiling 3 To check the refrigerant charge run the unit for 15 minutes and briefly remove the top cover The evaporator coil should be evenly frost coated across its surface At temperat...

Страница 6: ...of the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak cau...

Страница 7: ...s of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve 1 Conta...

Страница 8: ...noid Valve 3020814 1 5 Filter Dryer 3020901 1 6 Compressor 3022163 1 7 Solenoid Coil 3030421 1 8 Capacitor 3030908 1 9 Humidistat 3035145 1 10 Mains Lead 3035148 1 11 Fan Motor 3035788 1 12 Relay 3036...

Страница 9: ...H OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS S...

Страница 10: ......

Страница 11: ......

Страница 12: ...0264CS US C LILLY 1 4 1 1 1 1 Base 2 1 Left Base Support 3 1 Right Base Support 4 1 Drain Pipe 5 1 Condenser 6 1 Evaporator Coil 7 1 Fan Housing 8 4 Rubber Foot 9 1 Fan Inlet Ring 10 1 Fan Motor 11 1...