CS60 OWNERS MANUAL 

Drawing No.  :-  TPC302 
Issue :- 

Date :- 

12/07/04

 
 

TROUBLESHOOTING 

 
 
 

S

YMPTOM

 

C

AUSE

 

R

EMEDY

 

 

Unit inoperative 

1.  No power to unit 

1.  Check the power from power supply 
 panel 
 

Little or no airflow 

1.  Loose fan on shaft 
2.  Fan motor burnt out 
3.  Dirty refrigeration coils 
4.  Loose electrical wiring 
 
5.  Fuse blown or circuit breaker 
tripped 

1. Tighten fan 
2.  Replace the fan motor 
3. See 

Routine Maintenance

  Section 

4.  Check the wiring diagram to find 
 

fault and repair 

5.  Replace the fuse or reset the 
 circuit 

breaker 

 

Little or no water extraction 

1.  Insufficient air flow 
2. Compressor fault 
3.  Loss of refrigerant gas 
 

1.  Check all of the above 
2.  Contact the Factory Service Center 
3.  Contact the Factory Service Center 
 

Little or no defrost when 
required 

1. Faulty timer 
2.  Faulty by-pass valve 

1.  Contact the Factory Service Center 
2.  Contact the Factory Service Center 
 

Unit vibrates excessively 

1. Loose compressor 
 
2. Damaged fan 

1.  Tighten the nuts on the compressor 
mounts 
2. Replace fan 
 

Water flooding inside the 
machine 

1.  Drain pipe blocked/frozen 
2.  Drain pipe too high 
 
 
3.  Crimped or blocked tubing 

1.  Clear the obstruction 
2.  Ensure that no section of the 
drain hose is above the level of the 
 water 

outlet 

3. Straighten, clear, or replace tubing 

 
 
 
 
 
 

 
 

Ebac Industrial Products 

704 Middle Ground Boulevard 

Newport News 

VA 23606 

Telephone  (757) 873-6800   FAX  (757) 873-3632 

Sales Inquiries: 800-934-9194

Содержание CS60

Страница 1: ...CS60 OWNERS MANUAL Drawing No TPC302 Issue 1 Date 12 07 04 EBAC MODEL CS60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL...

Страница 2: ...quipped with a permanent drain The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling phase plus the additional heat generated...

Страница 3: ...TIONS MODEL CS60 HEIGHT 13 25 336 55mm WIDTH 13 75 349 25mm DEPTH 20 25 514 35mm WEIGHT 62 83lbs 28 5 kg AIRFLOW 360 CFM EXTRACTION 56 Pints Per Day At 80 F 60 RH POWER SUPPLY 115V 60Hz 1 ph FINISH Po...

Страница 4: ...eave the machine running for 15 minutes E Observe the evaporator coils through the rear upper grill to confirm frost operation i If the air temperature is below 80 F an even coating of frost should co...

Страница 5: ...ore does not need oiling 3 To check the refrigerant charge run the unit for 15 minutes and briefly remove the top cover The evaporator coil should be evenly frost coated across its surface At temperat...

Страница 6: ...of the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak cau...

Страница 7: ...s of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve 1 Conta...

Страница 8: ...noid Valve 3020814 1 5 Filter Dryer 3020901 1 6 Compressor 3022163 1 7 Solenoid Coil 3030421 1 8 Capacitor 3030908 1 9 Humidistat 3035145 1 10 Mains Lead 3035148 1 11 Fan Motor 3035788 1 12 Relay 3036...

Страница 9: ...H OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS S...

Страница 10: ......

Страница 11: ......

Страница 12: ...0264CS US C LILLY 1 4 1 1 1 1 Base 2 1 Left Base Support 3 1 Right Base Support 4 1 Drain Pipe 5 1 Condenser 6 1 Evaporator Coil 7 1 Fan Housing 8 4 Rubber Foot 9 1 Fan Inlet Ring 10 1 Fan Motor 11 1...

Отзывы: