manualshive.com logo in svg
background image

N+1

Switchover

Global Bus

Data

System

Sync

GLOBAL STATUS

Aux I/P

PABX

Routine
Speech

Alarms

Important
Message

!

AUX

OPERATIONAL

Beacons

System Reset
Beacon Test
Global Ticktone
Global Sense Test

LOCAL STATUS

Matrix

HMI  Amplifier  Beacon I/O   Power

Dist

Default
Config

Bgm

1    2    3

4    5    6

1      2

Power

Sonix 2mx

1      2

1      2

1      2

SONIX

TM 

2Mx 

Matrix Controller

Sonix

TM

 2Mx  Technical Manual

Содержание SONIX 2Mx

Страница 1: ...Alarms Important Message AUX OPERATIONAL Beacons System Reset Beacon Test Global Ticktone Global Sense Test LOCAL STATUS Matrix HMI Amplifier Beacon I O Power Dist Default Config Bgm 1 2 3 4 5 6 1 2 P...

Страница 2: ...FOR A PARTICULAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF T...

Страница 3: ...feedback 2Mx Sonix 2Mx Central controller Amp 350 d Sonix 350 W Power Amplifier with 100 V line output Eol1 Sonix Remote End of Line unit Eol8 Sonix Amplifier to 100 V line interface unit 8 channel SP...

Страница 4: ...Port Indicators 9 5 4 2 Bus connections 10 5 4 2 1 Split loop 10 5 4 3 Audio 10 5 4 4 Global bus 10 6 UNIT OPERATION 11 6 1 Front panel interface 11 6 1 1 Power on reset 11 6 1 2 Power 11 6 1 3 Backgr...

Страница 5: ...g 22 8 7 1 Data monitoring 22 8 7 2 Missing unit monitoring 22 8 7 3 Audio monitoring 22 8 7 4 Unit monitoring 22 8 8 Global Sense test 22 8 9 Access panel timeout 22 8 10 IO Audio timeout 22 9 CUSTOM...

Страница 6: ...N 1 TAP PCB CAT6A CONNECTIONS 19 FIGURE 18 N 1 TAP PCB CONTROL CONNECTIONS 20 FIGURE 19 2MX FAULT TREE 24 LIST OF TABLES TABLE 1 FAULT OUTPUT STATES 9 TABLE 2 DEFAULT CONFIGURATION INPUT STATE 9 TABLE...

Страница 7: ...nfigurable to allow customisation and modification to the whole Sonix PA GA system Central to the architecture of the Sonix PA GA system is a fully redundant self healing data loop connected via RJ45...

Страница 8: ...5 Beacon Bus Beacon bus connections 6 Sync Bus Sync bus connections 7 Power Bus Power bus connections 8 48V Input DC Input connector 9 Fault Output Fault relay output 10 Default Config Communications...

Страница 9: ...T6A The 8off pairs of both 8p8c RJ45 style sockets on the rear of the 2Mx are used to connect and communicate with the other units of a Sonix PA GA system Name Color Connected units Data Audio Amp Gre...

Страница 10: ...5 Split loop bus data flow The only exception to this is the global bus which is not capable of being a loop 5 4 3 Audio Audio is routed in a similar arrangement to the data control flow There are 2...

Страница 11: ...Sonix Hmi 26 see section 8 1 for more details 6 1 4 Local source inputs The local source inputs are comprised of Aux I P and PABX groups Each group has two indicators labelled 1 and 2 The indicators a...

Страница 12: ...ible states Pattern State Both off Error not a valid state Solid Green Healthy no issues Fast Flashing Green Duplicate unit ID seen not affecting system operation but should be corrected as soon as pr...

Страница 13: ...s not available for normal operation without accepting the ping set request first 6 1 13 Internal Fault Buzzer The 2Mx is provided with an internal buzzer that activates each time a new fault occurs T...

Страница 14: ...mplifiers Vw2 Beacon Controller Vw2 Beacon Controller Pbx Fire Gas Ms12 Io Io PABX 2Mx Central Controller 2Mx Central Controller 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli...

Страница 15: ...Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er Vw2 Beacon Controller Vw2 Beacon Controller Controller Vw2 Beacon Controller 2Mx Central Controller 2Mx Central Controller 350 d A...

Страница 16: ...Controller Vw2 Beacon Controller Ms12 A Side Access Panel Access Panel Access Panel Access Panel Access Panel Fire Gas Ms12 Pbx Vw2 Beacon Vw2 Beacon Vw2 Beacon Vw2 Beacon Controller Controller Contr...

Страница 17: ...er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er Vw2 Beacon Controller Vw2 Beacon Controller Controller Vw2 Be...

Страница 18: ...ler Controller Vw2 Beacon Controller Pbx Access Panel Access Panel Access Panel Access Panel Access Panel Fire Gas Pbx Ms12 Vw2 Beacon Vw2 Beacon Vw2 Beacon Vw2 Beacon Controller Controller Controller...

Страница 19: ...ap PCB is required for Amplifier Bus and a second for Beacon Bus if in use The connections for the beacon bus follow an identical pattern to amplifier bus connections shown Unit N Unit 1 Unit 2 Amp Bu...

Страница 20: ...ts of the resolved priority and general operation fault diagnostics The recommended maximum cable run for the sync bus is 100m please discuss with your local Eaton representative on longer distances 7...

Страница 21: ...Software See SAS manual for details 8 2 3 Amplifier faults In a typical PA GA system amplifiers are the most numerous items To aid with issue tracking the extended 2Mx Sync status report into SAS incl...

Страница 22: ...o returning A warning will be raised if a bus stops being a complete loop for audio see 6 1 8 Local Status indicators ote N Hmi Bus connected units access panels are partly wired in spurs they also mo...

Страница 23: ...Alarm Tone that is mixed into the Emergency Speech broadcast is set to approximately 12dB lower than the normal Attenuated Alarm This value can be customised to one of the following 1 1 2 5 4 6 8 5 1...

Страница 24: ...se Fault Split Loop Solid RED Key Flashing RED Flashing GREEN Ms12 Fault Io Audio Input Fault Amplifier Fault Missing Unit Missing Unit Duplicate Unit ID Duplicate Unit ID Duplicate Unit ID Data Routi...

Страница 25: ...red indicator is informing the user that there was an issue on the associated bus but it has been resolved To diagnose the issue users will need to study the log included with SAS assuming that the s...

Страница 26: ...aton and SONIX are registered trademarks All other trademarks are property of their respective owners Changes to the products to the information contained in this document and to prices are reserved s...

Отзывы: