11
POWERXL DM1 SERIES ADJUSTABLE FREQUENCY DRIVES
PUB53696—August 2020 www.eaton.com
•
Why Verify Pin operation is required.
•
Verify Pin operation is used to create pairing between
the device and PC. Pairing information is saved by the
device as well as the PC. There are different cases
when re-pairing needs to be done. They are as follows:
•
1. Device was never paired with the PC.
•
2. Device remembers only the last five pairing
information.
•
3. Pairing information is cleared in the device using
P11.49 (P11.6.3 on keypad),
•
Note:
If pairing is done between the device and PC,
and information is available (last five pairs - #2 and
pairing info. not cleared - #3) in device, pin verification is
not needed.
Additional Help
In the USA please contact the LV Drives Technical
Resource Center at 1-800-322-4986 or via email at
[email protected].
In Canada please contact the CSC EatonCare Distribution
and Control solutions at 1-800-268-3578 or via email at
[email protected].
All other supporting documentation is located on the Eaton
web site at www.eaton.com/drives.
Device
After inserting the communication DTM, the tool will
switch to show device DTMs. Select the device you want
to connect to and perform the same sets as used to add
communication DTM to add the device. Once the device is
added, depending on the communication device selected, a
window will pop up to set slave address or IP address of the
device (refer to the device specific DTM for an example of
setting the device addresses). Once the correct address is
set hit the set button.
Offline/online
With the devices added to the Network View, it gives the
ability to view an Offline parameter set of the device. By
stepping through the multi-frame selection screen, it will size
the offline file for the correct drive size or you can connect to
the device via the selected communication protocol.
Offline
The offline mode only allows for viewing and setting the
parameter without being connect to the device. Once you
have the parameters set, you can save this configuration and
load it to the drive when you are connected to it. To open an
offline file after adding the device to the network, it will open
the Multi-frame Settings window, set the drop-downs for the
required drive information, and hit set. This will then ask to
go through the Quick Start Wizard or open parameters. If
you click “Yes” for the Start-up Wizard, it will set through
parameter settings; once complete, it will open parameter
files. If “No” is selected for the Start-up Wizard, it will close
the Multi-frame and then double clicking on the device will
open parameter screen.
Figu
re 6. Selecting the device.