Power Xpert 4000/6000/8000 Meter Module
12
42
51
52
5
CT-
Current
Inputs
31
41
32
4
3
22
21
2
CW
11
1
WARN
ING
SCREW FLA
N
GE CA
BLE HOUSING REQUIRED
TO PREVENT OPEN
IN
G OF CT SECONDA
RIES
A
ND GEN
ERA
TION OF HA
ZA
RDOUS VOLTA
GE
Catalog#: PXM8251A1BB
Model#: PXM8200
MAC Address: CM XX:XX:XX:XX:XX:XX CE XX:XX:XX:XX:XX:XX
Serial#: XXXXXX
Style#: 65D8261G006
Current Inputs: 0.05-20A CAT III
Oper Temp: -20 TO 60°C
Voltage Inputs: 0-347 VL:N, 0-600 VL:L CAT III
Freq: 25-66, 350-450 Hz
TA: 2.5
CA: 0.2
MADE IN USA
Date Code: WYYYYMMDD
Rev: XXX
#7054769
U.S. Patents #5890097, #6906655, #6975951, #7050913
Transformer T
ype
VTR
:1
Meter Configuration
CTR
:5
Dept. Approval
No. AE-1582
Pulse Const./Disk Const. Meter T
ag
No.
(8.20)
(6.33)
(6.72)
CW
Volt
age Input
s
V4
V3
VT-
V2
V1
Auxiliary Volt
age
V
X-
Input
s
V7
V8
V6
PS1
-
100-240VAC
PXMPS-1
110-250VDC
50W Max
47-63 Hz
2
1
(+) L
(-) N
Rating
DO NOT HIPOT / DIELECTRIC TEST
REMOVE POWER BEFORE SERVICING
3
G
AVERTISSEMENT: CET EQUIPEMENT RENFERME PLUSIEURS
CIRCUITS SOUS TENSION. VOIR LE SCHEMA.
MORE THAN ONE LIVE CIRCUIT. SEE DIAGRAM.
WARNING
for technical support
1-800-809-2772 or 1-414-449-7100
www.eaton.com/electrical
Customer Satisfaction
<http://www.eaton.com/pxm
2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND
INCLUDING INTERFERENCE THAT MAY CAUSE
UNDESIRED OPERATION.
Power
2
1
3
10VA Source MAX
TXD
RXD
C
24+
SH
SH
DB
DA
CM6
-
3
2
1
CM5
-
3
2
1
Com 0 Display
10VA Source MAX
C
24+
SH
CM4
-
3
2
1
Com 1 RS485
TXD
RXD
SH
DB
DA
CM3
-
3
2
1
RXD/TXD
10/100 T (RJ45)
Local Configuration
Link
CM1
PXMCM-1
CE4
100 Fx (ST)
LAN/WAN
10/100 T (RJ45)
TXD/RXD
Com 2 RS485
Link
Com 3 RS232
1
CE3
-
2
3
DA
RXD
TXD
DTE
TXDRXD
SH
DB
CE2
Tx
CE1-
Rx
PXMCE-B
6
5A 240VAC
30VDC
9
8
7
SELF SOURC
E
24VDC
5
4
3
2
IO3- 1
100mA 30VDC
4
IO2-
3
2
1
6
9
8
7
5
3
4
1
IO1-
2
R2B
R3B
R3C
R3A
R2A
R2C
R1B
R1C
S21
R1A
S22
S12
S11
DI6
DIS
DI8
DI7
DI5
DI4
DI3
DI1
DI2
S1 LED
PXMIO-B
Short
Warning!
unplugging
CT's before
Address
Base
15
13
1
3
5
11
9
7
Com
Reset
Status
Health
8.32 in
211.33 mm
8.20 in
208.3 mm
8.32 in
211.33 mm
6.72 in
208.3 mm
6.33 in
160.78 mm
7.36 in
186.9 mm
Power Xpert 4000/6000/8000 Display Module
www.eaton.com
IB02601007E
Page 21
3 Mounting and Wiring
Содержание Power Xpert Meter 4000
Страница 4: ......
Страница 6: ...Page 6 IB02601007E www eaton com 1 Introduction...
Страница 18: ...Page 18 IB02601007E www eaton com 2 Quick Start Guide for the Meter Module...
Страница 23: ...www eaton com IB02601007E Page 23 3 Mounting and Wiring...