List of event codes
Information – 239
811
Critical
Parallel negative power
Parallel power OK
Reduce output load
815
Critical
Calibration fault
Calibration OK
Service required
81E
Critical
Load unprotected
Load protected
-
7.5.2.2 Warning
Code
Severity
Active message
Non-active message
Advice
001
Warning
On battery
No more on battery
-
007
Warning
Fan fault
Fan OK
Service required
00B
Warning
Parallel UPS redundancy lost
Parallel UPS redundancy OK
Reduce output load
00E
Warning
Parallel UPS communication lost
Parallel UPS communication OK
Service required
00F
Warning
Parallel UPS not compatible
Parallel UPS compatibility OK
Service required
010
Warning
UPS power supply fault
UPS power supply OK
Service required
011
Warning
Parallel UPS protection lost
Parallel UPS protection OK
Reduce output load
012
Warning
Parallel UPS measure inconsistent
Parallel UPS measure OK
Service required
103
Warning
Utility breaker open
Utility breaker closed
-
104
Warning
Input AC frequency out of range
Input AC frequency in range
-
106
Warning
Input AC not present
Input AC present
-
107
Warning
Input bad wiring
Input wiring OK
Check input wiring
108
Warning
Input AC voltage out of range (-)
Input AC voltage in range
-
109
Warning
Input AC voltage out of range (+)
Input AC voltage in range
-
110
Warning
Building alarm (through dry
contact)
Building alarm OK
-
11F
Warning
Building alarm (through Network
module)
Building alarm OK
-
10A
Warning
Input AC unbalanced
End of input AC unbalanced
-
200
Warning
Bypass phase out range
Bypass phase in range
-
201
Warning
Bypass not available
Bypass available
Service required
202
Warning
Bypass thermal overload
Bypass thermal OK
Reduce output load
203
Warning
Bypass temperature alarm
Bypass temperature OK
Check air conditioner
204
Warning
Bypass breaker open
Bypass breaker closed
-
205
Warning
Bypass mode
No more on bypass
-
206
Warning
Bypass frequency out of range
Bypass frequency in range
-
209
Warning
Bypass voltage out of range
Bypass voltage in range
-
20A
Warning
Bypass AC over voltage
End of bypass AC over voltage
-
20B
Warning
Bypass AC under voltage
End of bypass AC under voltage
-
20C
Warning
Bypass bad wiring
Bypass wiring OK
Check bypass wiring
300
Warning
DC bus + too high
DC bus + voltage OK
Service required
301
Warning
DC bus - too high
DC bus - voltage OK
Service required
302
Warning
DC bus + too low
DC bus + voltage OK
Service required
303
Warning
DC bus - too low
DC bus - voltage OK
Service required
304
Warning
DC bus unbalanced
DC bus OK
Service required
501
Warning
Charger temperature alarm
Charger temperature OK
Service required
Содержание INDGW-X2
Страница 1: ...UPS Industrial Gateway Card INDGW X2 User s Guide English 10 18 2021 2 2 3 ...
Страница 23: ...Configuring Modbus Installing the Network Management Module 25 ...
Страница 24: ...Configuring Modbus Installing the Network Management Module 26 ...
Страница 25: ...Configuring Modbus Installing the Network Management Module 27 ...
Страница 26: ...Configuring Modbus Installing the Network Management Module 28 ...
Страница 35: ...Home Contextual help of the web interface 37 3 2 7 1 3 Battery mode 3 2 7 1 4 Off mode ...
Страница 37: ...Home Contextual help of the web interface 39 3 2 7 2 2 Bypass mode 3 2 7 2 3 Battery mode ...
Страница 61: ...Protection Contextual help of the web interface 63 Example 4 Custom ...
Страница 62: ...Protection Contextual help of the web interface 64 Settings 1 Settings 2 ...
Страница 218: ...Default settings and possible parameters Information 220 ...
Страница 266: ...Acronyms and abbreviations Information 268 ...
Страница 273: ......