13
GREEN MOTION DC 22 EV CHARGER INSTALLATION MANUAL
MN192004EN November 2022 www.eaton.com
00
Title
5. Mounting and installation
5.1 Positioning the Green Motion DC 22 EV charger
5.2 Mounting
The installation position of the unit must meet the following conditions:
•
Manpower to install the product must be considered due to its weight and the weight of the floor-mount pedestal,
in accordance with local regulations.
•
The product must be installed in a place with relative humidity below 95 %.
•
Recommended operating temperature range of the unit is -25 °C to +45 °C.
•
Install the product to ensure easy access to the controls and connections.
•
When mounting on the wall, the surface on which the unit will be installed must be able to support its weight (55 kg).
•
The unit must be used at an altitude not exceeding 2000 m above sea level.
•
The product should be fixed at a height of 1000 mm above ground level, for optimal accessibility.
•
Keep at least 300 mm of free space from the left and right sides of the unit to allow for adequate air circulation.
•
The cable entries for power cables and the internet connection cable are through the bottom or rear of the charging
station.
The product can be wall-mounted or floor-mounted with a column (optional).
5.2.1 Site design
A site for electric vehicles (EVs) equipped with charging stations can be designed in different setups. This section is
intended to provide some valuable information on the placement of the EV chargers with respect to parking spaces.
As shown in the following figure, Eaton recommends installing the EV charger at the front and center of the parking
space, and each EV charger should serve one parking space.
Do not mount the product above or below flammable building materials.
Do not install the product in areas where highly flammable substances are present.
Do not install the product in areas subject to explosion hazard.
To prevent the risk of electric shock or other injury, check that there are no electrical or hydraulic lines in the
walls before drilling the mounting holes of the product.
Make sure there is enough free space for air circulation around the product. Local regulations may require
larger clearances.